MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jemermed.2014.06.015

Медицинская библиотека · The Journal of emergency medicine · 2014

Optimizing oxygen delivery in the critically ill: assessment of volume responsiveness in the septic patient.

de Witt Benjamin, Joshi Raj, Meislin Harvey, Mosier Jarrod M

СтатьяОбзорПеревод пока не подготовлен

Аннотация

BACKGROUND

Assessing volume responsiveness, defined as an increase in cardiac index after infusion of fluids, is important when caring for critically ill patients in septic shock, as both under- and over-resuscitation can worsen outcomes. This review article describes the currently available methods of assessing volume responsiveness for critically ill patients in the emergency department, with a focus on patients in septic shock.

OBJECTIVE

The single-pump model of the circulation utilizing cardiac-filling pressures is reviewed in detail. Additionally, the dual-pump model evaluating cardiopulmonary interactions both invasively and noninvasively will be described.

DISCUSSION: Cardiac filling pressures (central venous pressure and pulmonary artery occlusion pressure) have poor performance characteristics when used to predict volume responsiveness. Cardiopulmonary interaction assessments (inferior vena cava distensibility/collapsibility, systolic pressure variation, pulse pressure variation, stroke volume variation, and aortic flow velocities) have superior test characteristics when measured either invasively or noninvasively.

CONCLUSION

Cardiac filling pressures may be misleading if used to determine volume responsiveness. Assessment of cardiopulmonary interactions has superior performance characteristics, and should be preferentially used for septic shock patients in the emergency department.

Для цитирования: de Witt Benjamin, Joshi Raj, Meislin Harvey, Mosier Jarrod M. Optimizing oxygen delivery in the critically ill: assessment of volume responsiveness in the septic patient.. The Journal of emergency medicine. 2014. DOI: 10.1016/j.jemermed.2014.06.015.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.