DOI 10.1080/14796678.2025.2457881

Медицинская библиотека · Future cardiology · 2025

Comparison of in-clinic assessment of 6MWT by conventional method and using wearable sensors for patients with ATTR-CM.

Soman Prem, Khouri Michel G, Lenihan Daniel, Reyentovich Alex, Sperry Brett W, Sowalsky Kristen, Bai Yun, Du Jing, Katz Leonid, Siddhanti Suresh, Fox Jonathan C

Клиническое исследование III фазыСравнительное исследованиеСтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

INTRODUCTION

The 6-minute walk test (6MWT) is used to assess submaximal exercise capacity in clinical trials. Conducting the 6MWT can be challenging when patients cannot visit the clinic due to physical/travel limitations. This pilot study assessed the feasibility of conducting the 6MWT using wearable sensors for patients with transthyretin amyloid cardiomyopathy.

METHODS

Participants were enrolled in the phase 3 ATTRibute-CM trial. Sensors were positioned on patients' feet and lower back during the 6MWT. The 6-minute walk distance (6MWD) was compared with the distance measured by a trained observer during a concurrent conventional test. Pearson and concordance correlation coefficients were estimated.

RESULTS

Twelve participants from five centers participated; 11 had evaluable data. Mean 6MWD was 330.3 m (conventional method) and 335.1 m (wearable sensors); mean difference (SD) was 4.7 m (10.95). Pearson and concordance correlation coefficients for 6MWD were 0.998 (95% CI: 0.992-0.999) and 0.997 (95% CI: 0.991-0.999), respectively.

CONCLUSIONS

The 6MWD measured using wearable sensors and by the conventional method were closely correlated. Conducting the 6MWT with wearable sensors may be feasible and as reliable as the conventional method in a monitored clinic setting. Whether at-home 6MWD measured by wearable sensors correlates with in-clinic monitoring deserves further study.

CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov identifier is NCT03860935.

Для цитирования: Soman Prem, Khouri Michel G, Lenihan Daniel, Reyentovich Alex, Sperry Brett W, Sowalsky Kristen, Bai Yun, Du Jing, Katz Leonid, Siddhanti Suresh, Fox Jonathan C. Comparison of in-clinic assessment of 6MWT by conventional method and using wearable sensors for patients with ATTR-CM.. Future cardiology. 2025. DOI: 10.1080/14796678.2025.2457881.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.