MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1055/s-0040-1721822

Медицинская библиотека · Journal of neurological surgery. Part B, Skull base · 2020

A Single Layer Synthetic Dural Substitute Inlay is an Effective Sellar Reconstruction Technique in Endoscopic Transsphenoidal Pituitary Surgery.

Chaskes Mark B, Khoury Tawfiq, Chitguppi Chandala, Lavergne Pascal, Nyquist Gurston G, Rabinowitz Mindy R, Rosen Marc R, Evans James J

СтатьяПеревод пока не подготовлен

Аннотация

Objectives  A variety of endonasal sellar repair techniques have been described; many are complex, multilayered, and carry potential morbidity. We propose an effective, technically simple single-layer repair for select sellar defects, including those with an intraoperative cerebrospinal fluid (CSF) leak. Our technique utilizes only a synthetic dural substitute inlay and dural sealant glue without packing or lumbar drainage. Design  This is a retrospective review-based study. Setting  This study was conducted at tertiary care center. Participants  Patients who underwent endoscopic transsphenoidal surgery for pituitary adenoma and sellar reconstruction with the aforementioned inlay technique. Patients were selected for this technique if they had an identified intraoperative CSF leak, a patulous diaphragm (expanded and thinned diaphragma sella), or a comorbidity excluding them from a simpler onlay only reconstruction. Outcome Measures  Postoperative CSF leak and sinonasal morbidity included in the study. Results  A total of 409 subjects were identified; 368 were initial resections. Gross total resection of the pituitary adenoma was achieved in 356 (87.0%) cases. Average tumor size was 2.6 ± 1.1 cm. Average tumor volume was 10.8 ± 12.1 cm 3 . There were 135 intraoperative CSF leaks and 196 patulous diaphragms. There were five postoperative CSF leaks (1.2%), all of which occurred in the first half of our series. Pre- and postoperative sino-nasal outcomes test-22 scores were 19.2 ± 18.2 and 18.8 ± 21.3 ( p  = 0.492), respectively. Conclusion  A synthetic dural substitute inlay and dural sealant glue is an excellent single-layer repair for sellar defects, even those with an intraoperative CSF leak. This technique is highly effective in preventing postoperative CSF leaks and does not utilize packing or lumbar drainage. It also avoids the potential cost and morbidity associated with more complex and multilayered closures.

Для цитирования: Chaskes Mark B, Khoury Tawfiq, Chitguppi Chandala, Lavergne Pascal, Nyquist Gurston G, Rabinowitz Mindy R, Rosen Marc R, Evans James J. A Single Layer Synthetic Dural Substitute Inlay is an Effective Sellar Reconstruction Technique in Endoscopic Transsphenoidal Pituitary Surgery.. Journal of neurological surgery. Part B, Skull base. 2020. DOI: 10.1055/s-0040-1721822.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.