MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10103-022-03534-y

Медицинская библиотека · Lasers in medical science · 2022

Comparison of visual outcomes between 120-µm and 140-µm cap thicknesses 12 months after small incision lenticule extraction.

Gülmez Mehmet, Ural Fatihoğlu Özlem, Tekçe Abdülhakim

СтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

To compare visual and refractive outcomes as well as changes in high-order aberrations in patients with 120- versus 140-µm cap thicknesses 12 months after small incision lenticule extraction. Ninety-four patients were randomized to receive small incision lenticule extraction with either a 120-µm cap thickness (n = 47) or a 140-µm cap thickness (n = 47) to treat myopia or myopic astigmatism, if not both. In an analysis of right eyes only during the 12-month follow-up period, uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), refractive outcomes, and high-order aberrations were evaluated. The distribution of patients by age and sex between the groups did not differ significantly (P = .803 and P = .680, respectively). CDVA, spherical and cylindrical refraction, and changes in total high-order aberration, spherical aberration, coma, and trefoil were similar between the groups at 6 and 12 months, postoperatively. However, UDVA was statistically significantly higher in patients with 140-μm cap thicknesses than with 120-μm cap thicknesses at 6 and 12 months postoperatively (P < .001 and P < .001, respectively). Patients with 140-µm cap thickness showed greater improvement in UDVA than ones with 120-µm cap thickness at 12-month follow-up (P = .005). Both 120- and 140-μm cap thicknesses in small incision lenticule extraction were safe and effective thicknesses for correcting myopia or myopic astigmatism. The patients with 140-μm cap thickness had better improvement in UDVA after 12-month follow-up compared to patients with 120-μm cap thickness.

Для цитирования: Gülmez Mehmet, Ural Fatihoğlu Özlem, Tekçe Abdülhakim. Comparison of visual outcomes between 120-µm and 140-µm cap thicknesses 12 months after small incision lenticule extraction.. Lasers in medical science. 2022. DOI: 10.1007/s10103-022-03534-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.