DOI 10.1038/s41433-022-01964-0
Effect of capsular bend on the rotational stability of toric intraocular lens.
Аннотация
PURPOSE: To assess the effect of capsular bend and axial length on the rotational stability of toric IOL.
METHODS
The prospective study included patients with preexisting astigmatism that were implanted with Acrysof IQ Toric IOL. According to the pre‑operative axial length, all patients were divided into 2 groups: high myopia (AL ≥ 26 mm) group, and emmetropia or low to moderate myopia group (AL <26 mm). High-speed Swept-source Optical Coherence Tomography (SS-OCT) radial scanning was performed after pupil dilation to obtain the toric IOL axial orientation and capsular bending index (CBI) at 1-day, 1-week, 1-month and 3-month intervals postoperatively. The correlation between the rotation of toric intraocular lens and the axial length or CBI was subsequently analyzed.
RESULTS
68 eyes of 57 patients were included in the research. The rotation of toric IOL within the high myopia group was greater than the control group (P = 0.001, 1month postoperative). Capsular contact with the IOL was delayed in highly myopic eyes, although the results were not statistically significant (P = 0.094, 1-month postoperatively). There was a positive correlation between the degree of rotation and axial length at the interval found between 1-week and 1-month after the operation (r = 0.333, P = 0.005). There was a significant negative correlation between the IOL rotational speed and CBI (P < 0.001). The regression equation was Y = -0.441*X + 1.712 (R2 = 0.323, P < 0.001).
CONCLUSION
There was a significant negative correlation between the IOL rotation speed and the CBI, while the influence of the axial length and capsular bending mainly occurred between one week and one month after the operation.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.