MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/11206721221077541

Медицинская библиотека · European journal of ophthalmology · 2022

Long-term efficacy and safety profiles following small incision lenticule extraction in eyes with ≥ 5-year follow-up.

Papa-Vettorazzi Mario Renato, Güell-Villanueva José Luis, Cruz-Rodriguez José Benjamín, Moura-Coelho Nuno, Artells-de Jorge Nuria, Elies-Amat Daniel

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate long-term efficacy, safety, predictability and stability (refractive and keratometric) of myopic and myopic astigmatism correction with Small Incision Lenticule Extraction (SMILE).

METHODS

Single center retrospective review of eyes undergoing SMILE from 2012-2015. Forty-two eyes (23 patients) with ≥ 5-year follow-up. Variables analyzed were preoperative, 3-month, 1-year and last follow-up uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), manifest refraction, spherical equivalent (SE) and mean keratometry. Descriptive statistics were performed and results reported following the Standard for Reporting Astigmatism Outcomes.

RESULTS

Mean follow-up of 5.98 ± 0.90 years. Mean preoperative SE was -5.26 ± 1.22D (range -2.50 to -8.12D). Mean preoperative cylinder was -0.66 ± 0.61D (range 0.00 to -2.25D). Efficacy and safety indices were 0.86 and 0.98, respectively. In total, 81% of operated eyes achieved an UDVA of ≥ 0.09 logMar (20/25 Snellen). At the last follow-up, ≥1 line of CDVA was gained in 14% of eyes. Five percent lost 1 line of CDVA, and no eye loss ≥2 lines of CDVA. Sixty-nine percent of eyes were within ± 0.50D and 86% within ± 1.00D of the attempted SE correction. Ninety-one percent of eyes had ≤0.50D of postoperative astigmatism and 71% were within ± 15° from the intended correction axis. At the final follow-up, a statistically significant myopic regression of 0.19 ± 0.50D was observed (p = 0.01).

CONCLUSIONS

Long-term results demonstrate that SMILE is effective, predictable and safe. SMILE has good stability, low regression compared to LASIK, and no signs of corneal ectasia staging within our standard criteria.

Для цитирования: Papa-Vettorazzi Mario Renato, Güell-Villanueva José Luis, Cruz-Rodriguez José Benjamín, Moura-Coelho Nuno, Artells-de Jorge Nuria, Elies-Amat Daniel. Long-term efficacy and safety profiles following small incision lenticule extraction in eyes with ≥ 5-year follow-up.. European journal of ophthalmology. 2022. DOI: 10.1177/11206721221077541.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.