MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajem.2026.08.035

Медицинская библиотека · The American journal of emergency medicine · 2026

Can point-of-care high sensitivity troponin improve efficiency: a multisite US study.

Mahler Simon A, Ashburn Nicklaus P, Villenthi Akalya, Pearson David A, Pugh Hannah D, Hutchison Benjamin T, Supples Michael W, Snavely Anna C

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

New point-of-care (POC) high sensitivity troponin (hs-cTn) assays could improve chest pain care efficiency. This study seeks to determine whether implementation of POC hs-cTn reduces key Emergency Department (ED) time metrics.

METHODS

A prospective cohort study was conducted at three U.S. EDs (February-September 2025). Adults without STEMI and at least one hs-cTnI ordered were accrued. Blood samples were collected simultaneously for POC hs-cTnI measurement on an i-STAT 1 analyzer (Abbott Laboratories) and central laboratory hs-cTnI measurement (Beckman Coulter). Following POC hs-cTn measures, providers were surveyed regarding potential disposition and treatment decisions which were compared to actual disposition times. Turnaround time, time-to-disposition, and ED length of stay for POC versus central laboratory measures were compared using Wilcoxon signed-rank tests.

RESULTS

During the study period, 602 patients were accrued, of which 48% (286/602) were female and median age was 60 years (IQR: 50-70). POC hs-cTnI had a median turnaround time of 16 min (IQR: 15-17) compared to 52 min (IQR: 45-61) for the central laboratory, a 36-min difference (p < 0.001). Median time to potential disposition decision using POC was 222 min (IQR: 144-320) versus 273 min (IQR: 219-382) for central laboratory measures, a difference of 51 min (p < 0.001). The median potential ED length of stay was 325 min (IQR: 224-513) for POC versus 387 min (IQR: 276-564) for the central laboratory, yielding a potential reduction of 62 min (p < 0.001).

CONCLUSIONS

POC hs-cTnI measurement reduced turnaround time and produced substantive potential reductions in time-to-disposition decision and ED length of stay.

TRIAL REGISTRATION: NCT06899776.

Для цитирования: Mahler Simon A, Ashburn Nicklaus P, Villenthi Akalya, Pearson David A, Pugh Hannah D, Hutchison Benjamin T, Supples Michael W, Snavely Anna C. Can point-of-care high sensitivity troponin improve efficiency: a multisite US study.. The American journal of emergency medicine. 2026. DOI: 10.1016/j.ajem.2026.08.035.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.