DOI 10.1097/j.jcrs.0000000000000615

Медицинская библиотека · Journal of cataract and refractive surgery · 2021

Adjustment of intraocular lens tilt during intrascleral fixation assisted by intraoperative OCT.

Fukumoto Ryuki, Inoue Makoto, Ishida Tomoka, Koto Takashi, Hirakata Akito

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the efficacy of using intraoperative optical coherence tomography (iOCT) to adjust the tilting of an intraocular lens (IOL) during implantation with intrascleral fixation.

SETTING

Kyorin University Hospital, Tokyo, Japan.

DESIGN

Retrospective, case-control, single-center study.

METHODS

Thirty-seven eyes of 37 patients who had undergone pars plana vitrectomy with intrascleral fixation of an IOL by a single surgeon were retrospectively studied. The length of the externalized haptics was determined when the anterior surface of the IOL was parallel to the plane of the iris as observed by iOCT. The maximal IOL tilt relative to the visual axis and to the iris plane was measured by anterior segment OCT (CASIA2; Tomey Corp.).

RESULTS

Intraoperative crosssectional OCT (RESCAN 700: Carl Zeiss Meditec AG) scans were used to adjust the degree of IOL tilt in 23 eyes (iOCT group) and not used in 14 eyes (control group). The maximal angle of IOL tilt relative to the visual axis was significantly smaller in the iOCT group than that in the control group (5.45 ± 2.63 degrees vs 10.38 ± 10.48 degrees, P = .034). The maximal angle of the IOL tilt to the iris plane was also significantly smaller in the iOCT group than that in the control group (4.58 ± 1.86 degrees vs 9.60 ± 10.82 degrees; P = .040). The distance of decentration was greater in the iOCT group (0.56 ± 0.29 mm) than that of the control group (0.41 ± 0.41 mm, P = .005).

CONCLUSIONS

Intraoperative OCT can be used to adjust the degree of IOL tilt to reduce the lenticular astigmatism during intrascleral fixation surgery.

Для цитирования: Fukumoto Ryuki, Inoue Makoto, Ishida Tomoka, Koto Takashi, Hirakata Akito. Adjustment of intraocular lens tilt during intrascleral fixation assisted by intraoperative OCT.. Journal of cataract and refractive surgery. 2021. DOI: 10.1097/j.jcrs.0000000000000615.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.