Surgical endoscopy · 2021
Double anchor lock fixing method to prevent stent displacement in endoscopic ultrasound-guided gastroenterostomy: a porcine study.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Gao Haixin, Sun Siyu, Wang Guoxin, Guo Jintao, Wang Sheng, Liu Xiang, Ge Nan, Jiang Jitong, Sheng Shiyun
Аннотация
BACKGROUND: Endoscopic ultrasound-guided gastroenterostomy (EUS-GE) is widely used in patients with gastric outlet obstruction (GOO). Recurrence of obstruction symptoms caused by stent migration is the major reason for reintervention in EUS-GE. To solve this problem, we proposed developing a double anchor lock (DAL) fixing stent method for EUS-GE. The safety and efficacy of the DAL fixing stent method were evaluated in this study.
METHODS: Sixteen Bama miniature pigs were randomly divided into an experimental group (n = 8) and a control group (n = 8). A gastric outlet obstruction model was established for all the pigs. The experimental group was treated with the DAL fixing stent method for EUS-GE, while the control group was treated with EUS-GE. Three-month stent migration rate, remission rate of GOO, re-occlusion intervention rate, weight change, and incidence of procedure-related complications of EUS-GE were analyzed and estimated in the two groups.
RESULTS: EUS-GE was successfully completed in every subject in both groups. Symptoms of digestive tract obstruction can be relieved in all animals. The stent existence rate in the 3 months was higher in the experimental group than in the control group (87.5% vs. 12.5%, P = 0.012). Except for one animal in the experimental group in which there was pneumoperitoneum due to a stent insertion failure, no animal experienced bleeding or perforation.
CONCLUSION: The DAL fixing stent method, which can effectively prevent stent migration, is safe and simple. EUS-GE can effectively relieve the symptoms of digestive tract obstruction.
METHODS: Sixteen Bama miniature pigs were randomly divided into an experimental group (n = 8) and a control group (n = 8). A gastric outlet obstruction model was established for all the pigs. The experimental group was treated with the DAL fixing stent method for EUS-GE, while the control group was treated with EUS-GE. Three-month stent migration rate, remission rate of GOO, re-occlusion intervention rate, weight change, and incidence of procedure-related complications of EUS-GE were analyzed and estimated in the two groups.
RESULTS: EUS-GE was successfully completed in every subject in both groups. Symptoms of digestive tract obstruction can be relieved in all animals. The stent existence rate in the 3 months was higher in the experimental group than in the control group (87.5% vs. 12.5%, P = 0.012). Except for one animal in the experimental group in which there was pneumoperitoneum due to a stent insertion failure, no animal experienced bleeding or perforation.
CONCLUSION: The DAL fixing stent method, which can effectively prevent stent migration, is safe and simple. EUS-GE can effectively relieve the symptoms of digestive tract obstruction.