MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/medicina58101486

Медицинская библиотека · Medicina (Kaunas, Lithuania) · 2022

Safety and Feasibility of Single-Port Trans-Axillary Robotic Thyroidectomy: Experience through Consecutive 100 Cases.

Kang Il Ku, Park Joonseon, Bae Ja Seong, Kim Jeong Soo, Kim Kwangsoon

СтатьяПеревод пока не подготовлен

Аннотация

Background and

Objectives

Recently, the single-port (SP) robotic system was introduced for minimally invasive operative techniques. Thus, this study aimed to validate the safety and feasibility of SP trans-axillary robotic thyroidectomy (SP-TART) through experiences in a single tertiary institution. Materials and

Methods

This study retrospectively analyzed 100 consecutive patients who underwent SP-TART from October 2021 to June 2022 in Seoul St. Mary's Hospital in Seoul, Korea. We analyzed the clinicopathological characteristics and perioperative outcomes, including complications.

Results

Less than total thyroidectomy (LTT) was performed in 81, total thyroidectomy (TT) in 16, and TT with modified radical neck dissection (mRND) in 3 patients. The mean operation time (min) was 53.3 ± 13.7, 86.3 ± 15.1, and 245.7 ± 36.7 in LTT, TT, and TT with mRND, respectively. The mean postoperative hospital stay was 2.0 ± 0.2, 2.1 ± 0.3, and 3.7 ± 1.5 days, respectively. A total of 84 cases of thyroid cancer were included, and 97.6% of them (82 cases) were papillary carcinoma and the rest were follicular and poorly differentiated carcinomas. Regarding complications, five cases had major complications, including three cases of vocal cord palsy and two cases of transient hypoparathyroidism.

Conclusions

SP-TART is safe and feasible with a short operation time and a short length of hospital stay.

Для цитирования: Kang Il Ku, Park Joonseon, Bae Ja Seong, Kim Jeong Soo, Kim Kwangsoon. Safety and Feasibility of Single-Port Trans-Axillary Robotic Thyroidectomy: Experience through Consecutive 100 Cases.. Medicina (Kaunas, Lithuania). 2022. DOI: 10.3390/medicina58101486.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.