Transurethral catheterization of female domestic pigs with a Foley catheter.

Žel Jurij, Brankovič Jana, Klančnik Rok, Stopar Pintarič Tatjana, Cvetko Erika, Seliškar Alenka

СтатьяПеревод пока не подготовлен

Аннотация

This report describes transurethral catheterization with a Foley catheter in 19 anaesthetized, laterally recumbent female pigs with a chest circumference of 72.1 ± 4.2 cm and weighing approximately 40 kg. Catheterization within five minutes was successful in 78.9% of the pigs. Catheterization depth, measured as the distance between the bladder neck and the mucocutaneous junction of the vulva, was 14.5 ± 1.3 cm and correlated with chest circumference but not body length. Measurement of catheterization depth aids in optimal positioning and may prevent inflation of the Foley catheter in the urethra.