DOI 10.1016/j.euros.2021.01.013
Reduced Need for Urinary Bladder Catheterization in the Postanesthesia Care Unit After Implementation of an Evidence-based Protocol: A Prospective Cohort Comparison Study.
Аннотация
BACKGROUND
Postoperative urinary retention (POUR) is a known complication in the postanesthesia care unit (PACU). The variations in catheterization thresholds contribute to unnecessary invasive procedures.
OBJECTIVE
In the current study, we implemented an algorithm for a sterile intermittent catheterization (SIC) threshold of 800 ml with volume-dependent bladder scan intervals and compared the incidence of SIC with that of a matched patient cohort threshold of 400 ml.
DESIGN SETTING AND
PARTICIPANTS
This comparative study of two prospective historical cohorts represented two thresholds for POUR, set at 400 ml without a standardized bladder scan protocol and 800 ml with a volume-dependent bladder scan protocol.
OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS: The primary outcome was the frequency of catheterization during the PACU stay. Secondary outcomes evaluated patient safety aspects in occurrence of thresholds above 400/800 ml. The study was set at the PACU under the Department of Anesthesia, Center for Cancer and Organ Diseases, Rigshospitalet, Denmark.
RESULTS AND LIMITATIONS: In total, 741 patients were consecutively included, with 307 in the POUR-400 and 434 in the POUR-800 group, and with comparable group characteristics. Significantly fewer patients fulfilled the SIC/catheter a' demeure (CAD) criteria in the POUR-800 (5.0%) versus POUR-400 (14.3%) group, equivalent to a 65.0% relative reduction in SIC.
CONCLUSIONS
Implementation of a standardized ultrasound-guided protocol with volume-dependent scan intervals and an evidence-based catheterization threshold of 800 ml decreases the need for SIC by >65%, without increasing the need for urinary catheterization at the wards.
PATIENT SUMMARY: In this study, we implemented an algorithm for a sterile intermittent catheterization threshold of 800 ml with volume-dependent bladder scan intervals. A marked reduction was seen in catheterization in the postanesthesia care unit, without increasing catheterization rates at the ward.