MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/md.0000000000025490

Медицинская библиотека · Medicine · 2021

Indwelling catheter increases the risk of urinary tract infection in total knee arthroplasty: A meta-analysis of randomized controlled trials.

Shuai Mingying, Li Yueping

СтатьяМетаанализСистематический обзорПеревод пока не подготовлен

Аннотация

BACKGROUND

The purpose of this meta-analysis was to assess whether a urinary catheter is necessary for all patients in primary total knee arthroplasty (TKA).

METHODS

PubMed, EMBASE, the Cochrane Library, Web of Science, and China National Knowledge Infrastructure were systematically searched for randomized controlled trials (RCTs). All RCTs were compared with receive either an indwelling urinary catheter or no urinary catheter in TKA. Primary outcomes were urinary retention and urinary tract infection. Secondary outcomes were the length of stay, duration of the surgery, and the first urination time.

RESULTS

A total of 6 RCTs involving 1334 patients were included in the meta-analysis. No significant difference between the 2 groups was found in urinary retention (P = .52), length of stay (P = .38), duration of the surgery (P = .55). However, patients with an indwelling catheter were associated with a higher risk of urinary tract infections and longer time for the first urination than patients without indwelling catheters (P = .009 and P = .004).

CONCLUSION

The available evidence indicates that patients without using the indwelling catheters could reduce urinary tract infections and the time for the first urination, without increase in the incidence of urinary retention in primary TKA.

LEVEL OF EVIDENCE: Level I, therapeutic study.

Для цитирования: Shuai Mingying, Li Yueping. Indwelling catheter increases the risk of urinary tract infection in total knee arthroplasty: A meta-analysis of randomized controlled trials.. Medicine. 2021. DOI: 10.1097/md.0000000000025490.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.