MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1055/s-0043-1777308

Медицинская библиотека · Seminars in thrombosis and hemostasis · 2023

Description of an In Vitro Platelet Function Analyzer-PFA-100™.

Kundu Sourav K, Heilmann Eric J, Sio Reynaldo, Garcia Carmen, Davidson Rosa M, Ostgaard Roy A

СтатьяПеревод пока не подготовлен

Аннотация

This manuscript represents a republication of a manuscript originally published in STH in 1995. This republication is to help celebrate 50 years of publishing for STH. The original abstract follows.A new in vitro system for the detection of platelet dysfunction, PFA-100®, has been developed. It provides a quantitative measure of platelet function in anticoagulated whole blood. The system comprises a microprocessor-controlled instrument and a disposable test cartridge containing a biologically active membrane. The instrument aspirates a blood sample under constant vacuum from the sample reservoir through a capillary and a microscopic aperture cut into the membrane. The membrane is coated with collagen and epinephrine or adenosine 5'-diphosphate. The presence of these biochemical stimuli, and the high shear rates generated under the standardized flow conditions, result in platelet attachment, activation, and aggregation, slowly building a stable platelet plug at the aperture. The time required to obtain full occlusion of the aperture is reported as the "closure time." We have found that impairment of von Willebrand factor, or inhibition of platelet receptors glycoprotein Ib or IIb/IIIa with monoclonal antibodies or peptides, resulted in abnormal closure times. An antifibrinogen antibody, in contrast, failed to show any effect. The test appears to be sensitive to platelet adherence and aggregation abnormalities. The PFA-100® system has potential applications in routine evaluation of platelet function in the clinical setting because of its accuracy, case of operation, and rapid turnaround of results.

Для цитирования: Kundu Sourav K, Heilmann Eric J, Sio Reynaldo, Garcia Carmen, Davidson Rosa M, Ostgaard Roy A. Description of an In Vitro Platelet Function Analyzer-PFA-100™.. Seminars in thrombosis and hemostasis. 2023. DOI: 10.1055/s-0043-1777308.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.