MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/lary.24253

Медицинская библиотека · The Laryngoscope · 2013

Range image of the velopharynx produced using a 3-D endoscope with pattern projection.

Mishima Katsuaki, Nakano Asuka, Shiraishi Ruriko, Ueyama Yoshiya

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES/HYPOTHESIS: To measure movements of the velopharynx in detail, a novel method of producing range images of the velopharynx was developed using a 3-D endoscope. The purpose of this paper is to introduce this system and to clarify its accuracy.

STUDY

DESIGN

The standard errors of repeated measurements, intraclass correlation coefficients (ICC), ICC(1,1) for intrarater reliability, and ICC(2,1) for interrater reliability were measured using a phantom of the nasopharynx.

METHODS

An endoscopic measuring system was developed in which a pattern projection system was incorporated into a commercially available 3-D endoscope. Right and left images of the endoscope were integrated into one video file and digitized at a horizontal and vertical resolution of 640 × 480 pixels, as odd and even scanning lines, respectively. After separation of the video file into right and left images by interlace interpolation, correcting the distortion of the camera images, rectifying, and stereo-matching range images of the velopharynx were produced. The distances between two points, which were marked at an interval of 5 mm on the uvula and the pharynx of the phantom, were measured.

RESULTS

The standard errors of repeated measurements were 0.02 horizontally and 0.01 vertically. The ICC(1,1) and ICC(2,1) were 0.83 and 0.94, and both correlation coefficients were considered to be "almost perfect."

CONCLUSION

The present endoscopic measuring system provided relatively accurate and reliable range images of the velopharynx, and enabled quantitative analysis of movements of the velopharynx.

Для цитирования: Mishima Katsuaki, Nakano Asuka, Shiraishi Ruriko, Ueyama Yoshiya. Range image of the velopharynx produced using a 3-D endoscope with pattern projection.. The Laryngoscope. 2013. DOI: 10.1002/lary.24253.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.