DOI 10.1177/0310057x1003800130
Difficult double-lumen tube placement due to laryngeal web.
Аннотация
We present a case of difficult intubation in a patient with a laryngeal web. A 33-year-old male patient presented for open thoracotomy and had a previously undiagnosed laryngeal web, which complicated the placement of a double-lumen tube. A single-lumen tube was placed with the use of a bougie through the narrowed airway. With the subsequent use of an airway exchange catheter a double-lumen tube was positioned. Techniques for managing narrowing of the supraglottic airway are presented and the literature dealing with laryngeal webs is reviewed. In the setting of an unusual airway and thoracic surgery, ventilation via simpler techniques takes precedence over insertion of more complex tubes.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.