MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/17434440.2025.2553046

Медицинская библиотека · Expert review of medical devices · 2025

The development of a novel device to aid in capillary macro blood self-sampling via an iterative study design.

Herrijgers Corinne, Van Landeghem Ella, Vanroye Fien, Cuylaerts Vicky, Kenyon Chris, Vanbaelen Thibaut, Van Lent Kurt, Smekens Bart, Decuypere Saskia, Bosman Evi, De Cock Natalie, Couwenbergh Camille, Baert Ella, Wymeersch Rien, Sorgeloos Kristof, Beyers Koen, Dierickx Tim, Van den Bossche Dorien, Platteau Tom, De Baetselier Irith

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Blood sampling is essential for infectious disease diagnosis and monitoring but often requires venipuncture, limiting accessibility. Self-sampling offers a decentralized alternative, yet current macro-blood sampling methods are scarce. The device was developed to enable standardized, user-friendly self-sampling of ≥ 500 µL capillary fingerprick blood.

RESEARCH DESIGN AND

METHODS

Via an iterative, mixed-method approach, we optimized the Collect2Know device (C2K) across five prototypes (P1-P5). Usability, acceptability, and blood volume of each prototype were assessed among minimum 10 participants. A minimum threshold of 75% usability and acceptability, and 60% of users collecting minimum 500 µL guided device refinement.

RESULTS

The first prototype (P1) underperformed, leading to redesign. P2-P3 improved usability and acceptability but failed volume collection targets. P4 incorporated substantial improvements, making the prototype more intuitive, and 77.5% (31/40) achieved success in blood collection with usability and acceptability scores of 89.1% and 75.6%, respectively.

CONCLUSIONS

This study highlights the value of an iterative study-design, in the early stages of device development. The C2K device will facilitate capillary fingerprick macro-bloodsampling. By shifting routine blood sampling to decentralized settings, the C2K device may have the potential to enhance access to diagnostics, reduce healthcare burdens, and support public health efforts in both high- and low-resource settings.

Для цитирования: Herrijgers Corinne, Van Landeghem Ella, Vanroye Fien, Cuylaerts Vicky, Kenyon Chris, Vanbaelen Thibaut, Van Lent Kurt, Smekens Bart, Decuypere Saskia, Bosman Evi, De Cock Natalie, Couwenbergh Camille, Baert Ella, Wymeersch Rien, Sorgeloos Kristof, Beyers Koen, Dierickx Tim, Van den Bossche Dorien, Platteau Tom, De Baetselier Irith. The development of a novel device to aid in capillary macro blood self-sampling via an iterative study design.. Expert review of medical devices. 2025. DOI: 10.1080/17434440.2025.2553046.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.