DOI 10.1515/dx-2025-0065

Медицинская библиотека · Diagnosis (Berlin, Germany) · 2025

Minimizing the discard blood volume from the central venous catheter for routine laboratory testing in adult intensive care unit.

Lapić Ivana, Kostelac Josipa, Bielen Luka, Vujaklija Brajković Ana, Rupčić Gračanin Ivana, Rogić Dunja, Radonić Radovan

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

The aim was to reduce blood loss related to laboratory blood sampling by decreasing the discard blood volume from the central venous catheter (CVC) from 10 to 3 mL, and replacing the 3 mL tube for complete blood count (CBC) with a 2 mL tube. A comparison study was performed, and after introduction of this modified protocol the decrease in withdrawn blood was calculated.

METHODS

In 52 adult inpatients at the ICU 3 mL of blood was discarded from the CVC, and blood was drawn in a 5 mL serum tube and a 2 mL EDTA tube (test samples), followed by subsequent sampling for routine laboratory testing using the same blood tubes (routine samples). In paired test and routine samples, clinical chemistry testing and CBC were performed.

RESULTS

High correlations (ρ>0.90) were obtained for the majority of parameters. Small constant difference was obtained for hemoglobin. Small significant biases were observed for hemoglobin, MCHC, albumin, ALT, calcium, chlorides, MCV and glucose, however, being below the biases of the analytical methods. No statistically significant differences between test and routine samples were found for any of the assessed tests (p>0.05). Implementation of the 3 mL discard blood volume protocol and transition to a smaller volume tube for CBC reduced the amount of withdrawn blood by almost half (46 %).

CONCLUSIONS

The 3 mL discard blood volume from the CVC can be safely used for routine hematology and clinical chemistry testing. The dual approach assessed herein can contribute to reduction of iatrogenic blood loss.

Для цитирования: Lapić Ivana, Kostelac Josipa, Bielen Luka, Vujaklija Brajković Ana, Rupčić Gračanin Ivana, Rogić Dunja, Radonić Radovan. Minimizing the discard blood volume from the central venous catheter for routine laboratory testing in adult intensive care unit.. Diagnosis (Berlin, Germany). 2025. DOI: 10.1515/dx-2025-0065.