Аннотация

PURPOSE: To assess adding straylight measurements to the indication for cataract surgery.

SETTING

Onze Lieve Vrouwe Hospital, Amsterdam, and Zonnestraal Eye Clinic, Hilversum, The Netherlands.

DESIGN

Prospective interventional cohort study.

METHODS

Before and after cataract extraction, corrected distance visual acuity (CDVA) and straylight were recorded in all patients. Subjective complaints were documented by the 39-item National Eye Institute Visual Function Questionnaire (NEI VFQ-39) and a straylight questionnaire.

RESULTS

The population comprised 217 patients with a mean age of 72 years ± 9.12 (SD) (range 29 to 90 years). Preoperatively, the mean straylight was 1.55 ± 0.29 log(s) and the mean CDVA, 0.28 ± 0.21 logMAR. Visual acuity and straylight showed little correlation (R(2) = 0.08). The mean postoperative improvement in CDVA was 0.26 ± 0.20 logMAR (range -0.12 to 1.12 logMAR) and in straylight, 0.31 ± 0.32 log(s) (range -0.50 to 1.27 log[s]). The preoperative breakeven point (50% chance of postoperative improvement) was 0.06 logMAR for CDVA and 1.29 log(s) for straylight. Preoperative and postoperative questionnaires showed straylight had almost the same influence as visual acuity on quality of vision.

CONCLUSIONS

Straylight and visual acuity measure different aspects of quality of vision and influenced subjective visual quality almost equally. When straylight was added to preoperative considerations of cataract extraction, postoperative results were more predictable.

FINANCIAL DISCLOSURE: The Netherlands Academy of Arts and Sciences has a proprietary interest in the C-Quant Straylight meter. No author has a financial or proprietary interest in any material or method mentioned.

Для цитирования: van der Meulen Ivanka J E, Gjertsen Jennifer, Kruijt Bastiaan, Witmer Jan Peter, Rulo Alexander, Schlingemann Reinier O, van den Berg Thomas J T P. Straylight measurements as an indication for cataract surgery.. Journal of cataract and refractive surgery. 2012. DOI: 10.1016/j.jcrs.2011.11.048.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.