MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3341/kjo.2012.26.2.97

Медицинская библиотека · Korean journal of ophthalmology : KJO · 2012

Anterior chamber configuration changes after cataract surgery in eyes with glaucoma.

Kim Martha, Park Ki Ho, Kim Tae-Woo, Kim Dong Myung

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate changes in anterior chamber depth (ACD) and angle width induced by phacoemulsification and intraocular lens (IOL) implantation in eyes with glaucoma, using anterior segment optical coherence tomography (AS-OCT).

METHODS

Eleven eyes of 11 patients with angle-closure glaucoma (ACG) and 12 eyes of 12 patients with open-angle glaucoma (OAG) underwent phacoemulsification and IOL implantation. Using AS-OCT, ACD and angle parameters were measured before and 2 days after surgery. Change in intraocular pressure (IOP) and number of ocular hypotensive drugs were evaluated.

RESULTS

After surgery, central ACD and angle parameters increased significantly in eyes with glaucoma (p < 0.05). Prior to surgery, mean central ACD in the ACG group was approximately 1.0 mm smaller than that in the OAG group (p < 0.001). Post surgery, mean ACD of the ACG group was still significantly smaller than that of the OAG group. No significant differences were found in angle parameters between the ACG and OAG groups. In the ACG group, postoperative IOP at the final visit was significantly lower than preoperative IOP (p = 0.018) and there was no significant change in the number of ocular hypotensive medications used, although clinically, patients required fewer medications. In the OAG group, the IOP and number of ocular hypotensive drugs were almost unchanged after surgery.

CONCLUSIONS

The ACD and angle width in eyes with glaucoma increased significantly after phacoemulsification and IOL implantation. Postoperative ACD significantly differed between the ACG and OAG groups, whereas angle parameters did not differ.

Для цитирования: Kim Martha, Park Ki Ho, Kim Tae-Woo, Kim Dong Myung. Anterior chamber configuration changes after cataract surgery in eyes with glaucoma.. Korean journal of ophthalmology : KJO. 2012. DOI: 10.3341/kjo.2012.26.2.97.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.