Effects of corneal thickness and axial length on intraocular pressure and ocular pulse amplitude before and after cataract surgery.

Tabuchi Hitoshi, Kiuchi Yoshiaki, Ohsugi Hideharu, Nakakura Shunsuke, Han Zaigen

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To investigate the relationship between the biophysical properties of the cornea and eye on the intraocular pressure (IOP) and ocular pulse amplitude (OPA) before and after cataract surgery.

DESIGN

Intervention study.

PARTICIPANTS

The left eyes of 311 patients.

METHODS

The left eyes of 338 patients undergoing cataract surgery without other eye pathology were studied. IOP and OPA were recorded by dynamic contour tonometry (DCT) 1 week before and 14 weeks after cataract surgery. The axial length, corneal curvature, central corneal thickness, anterior chamber depth, and anterior chamber angle were measured 1 week before cataract surgery. Multiple regression analyses of these factors to the preoperative OPA were performed. The difference between the pre- and postoperative IOP and OPA were investigated by paired t tests.

RESULTS

Three hundred and eleven of 338 eyes were analyzed. The preoperative OPA was negatively correlated with axial length (β = -0.24, p < 0.0001) and positively correlated with the preoperative IOP (β = 0.13, p < 0.0001). The average OPA was significantly decreased after cataract surgery (p < 0.0001). The mean change in postoperative OPA was -0.45 ± 0.63 mm Hg (95% CI -0.52 to -0.38 mm Hg).

CONCLUSIONS

The preoperative OPA was negatively correlated with axial length as reported. A significant decrease in OPA was observed after the cataract surgery.

Для цитирования: Tabuchi Hitoshi, Kiuchi Yoshiaki, Ohsugi Hideharu, Nakakura Shunsuke, Han Zaigen. Effects of corneal thickness and axial length on intraocular pressure and ocular pulse amplitude before and after cataract surgery.. Canadian journal of ophthalmology. Journal canadien d'ophtalmologie. 2011. DOI: 10.1016/j.jcjo.2011.05.015.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.