MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcrs.2010.11.026

Медицинская библиотека · Journal of cataract and refractive surgery · 2011

Effects of preoperative corneal astigmatism orientation on results with a low-cylinder-power toric intraocular lens.

Ernest Paul, Potvin Richard

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate refractive results with a low-cylinder-power toric intraocular lens (IOL) and the effect of preoperative corneal astigmatism orientation on results.

SETTING

Private practice, Jackson, Michigan, USA.

DESIGN

Comparative case series.

METHODS

This retrospective review of clinical records comprised patients with 0.75 to 1.38 diopters (D) of preoperative corneal astigmatism who had uneventful cataract surgery and AcrySof T3 toric or AcrySof IQ spherical monofocal IOL implantation. Surgically induced astigmatism (SIA) was calculated for eyes with postoperative keratometry results. Postoperative refractive astigmatism between groups and subgroups was compared based on the orientation of preoperative corneal astigmatism.

RESULTS

Of the eyes, 185 had a toric IOL and 138 had a spherical IOL. The mean preoperative corneal astigmatism was 1.06 D, with no significant difference between IOL groups or by axis of astigmatism. The mean SIA was 0.25 D, with no significant difference between IOL groups. The mean postoperative refractive astigmatism was statistically significantly lower in the toric IOL group than in the spherical IOL group (0.31 D versus 1.06 D; P<.001). The axis of preoperative corneal astigmatism was not a significant factor in the toric IOL group. In the spherical IOL group, the residual astigmatism was slightly higher for with-the-rule than for against-the-rule astigmatism (1.07 D versus 0.70 D; P<.001).

CONCLUSIONS

The mean refractive astigmatism after cataract surgery in patients with 0.75 D to 1.38 D of corneal astigmatism was significantly lower when a toric IOL was implanted. Postoperative refractive astigmatism with the toric IOL was independent of preoperative corneal astigmatism axis orientation.

FINANCIAL DISCLOSURE: Neither author has a financial or proprietary interest in any material or method mentioned.

Для цитирования: Ernest Paul, Potvin Richard. Effects of preoperative corneal astigmatism orientation on results with a low-cylinder-power toric intraocular lens.. Journal of cataract and refractive surgery. 2011. DOI: 10.1016/j.jcrs.2010.11.026.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.