MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcrs.2010.08.043

Медицинская библиотека · Journal of cataract and refractive surgery · 2011

Visual outcomes and optical performance of a monofocal intraocular lens and a new-generation multifocal intraocular lens.

Alió Jorge L, Piñero David P, Plaza-Puche Ana B, Chan Maria Joanna Rodriguez

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To compare visual acuity outcomes and ocular and intraocular optical quality in patients with a monofocal intraocular lens (IOL) or a multifocal IOL with rotational asymmetry.

SETTING

Vissum Corporation, Alicante, Spain.

DESIGN

Comparative case series.

METHODS

Consecutive eyes of cataract patients were divided into 2 groups. One group received a Lentis Mplus LS-312 multifocal IOL and the other, an Acri.Smart 48S monofocal IOL. Distance and near visual acuities, contrast sensitivity, intraocular aberrations (global minus corneal aberrations), and defocus curves were evaluated preoperatively and postoperatively during a 3-month follow-up.

RESULTS

The study evaluated 52 eyes of 29 patients (age range 36 to 87 years); 24 eyes were in multifocal IOL group and 28 eyes, in the monofocal IOL group. Both groups had a significant improvement in uncorrected and corrected distance visual acuities and in distance-corrected near visual acuity (DCNVA) postoperatively (P ≤ .04). The multifocal IOL group had significantly better uncorrected near acuity and DCNVA (Jaeger [J] 5 versus J2) (both P < .01). The defocus curves showed significantly better visual acuities in the multifocal group at several levels of defocus. The multifocal group had significantly higher amounts of postoperative intraocular primary coma (P<.01), especially in eyes with significant IOL tilt, although there were no significant differences in contrast sensitivity between the 2 IOL groups (P ≥ .25).

CONCLUSIONS

The new-generation multifocal IOL restored distance, intermediate, and near visual function after cataract surgery. The optical quality with this type of IOL was particularly affected by IOL tilt and decentration.

Для цитирования: Alió Jorge L, Piñero David P, Plaza-Puche Ana B, Chan Maria Joanna Rodriguez. Visual outcomes and optical performance of a monofocal intraocular lens and a new-generation multifocal intraocular lens.. Journal of cataract and refractive surgery. 2011. DOI: 10.1016/j.jcrs.2010.08.043.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.