Аннотация

PURPOSE: The effect of computed tomography (CT) density-based, non-uniform photon attenuation correction (AC) on lung perfusion distribution and the clinical significance were evaluated.

MATERIALS AND

METHODS

40 patients with pulmonary emphysema, 32 with pulmonary thromboembolism, 25 with lung cancer and 8 normal controls underwent deep-inspiratory breath-hold (DIBrH) Tc-99m-MAA perfusion SPECT, using a dual-head SPECT system and a respiratory tracking device. Scatter-corrected DIBrH SPECT was automatically co-registered with DIBrH CT. AC of DIBrH SPECT was performed using an attenuation coefficient map of a variable-effective linear coefficient calculated from CT pixel density of the co-registered DIBrH CT. The effect of AC on pulmonary perfusion was evaluated by comparison with uncorrected SPECT.

RESULTS

After AC, lung perfusion in normal lungs was increased predominantly at deep lungs near the mediastinum and vertebrae and at the upper-middle lungs, with systematic increases of radioactivity (145 ± 28%) and significant enhancement of physiological gravitational ventral-dorsal gradient (P < 0.01). Throughout the lung diseases, AC significantly enhanced perfusion defect clarity and heterogeneity (P < 0.001), without noticeable artifacts. The correlation between perfusion heterogeneity and the lung diffusing capacity for carbon monoxide was significantly improved in patients with emphysema (P < 0.005).

CONCLUSION

CT density-based, non-uniform AC of DIBrH perfusion SPECT provides better assessment of physiologic or impaired perfusion distributions in normal and lung diseases.

Для цитирования: Suga Kazuyoshi, Okada Munemasa, Kunihiro Mitsue, Iwanaga Hideyuki, Matsunaga Naofumi. Clinical significance of CT density-based, non-uniform photon attenuation correction of deep-inspiratory breath-hold perfusion SPECT.. Annals of nuclear medicine. 2011. DOI: 10.1007/s12149-010-0461-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.