MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.phro.2022.11.003

Медицинская библиотека · Physics and imaging in radiation oncology · 2022

Evaluating the Effectiveness of Deep Learning Contouring across Multiple Radiotherapy Centres.

Walker Zoe, Bartley Gary, Hague Christina, Kelly Daniel, Navarro Clara, Rogers Jane, South Christopher, Temple Simon, Whitehurst Philip, Chuter Robert

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND PURPOSE: Deep learning contouring (DLC) has the potential to decrease contouring time and variability of organ contours. This work evaluates the effectiveness of DLC for prostate and head and neck across four radiotherapy centres using a commercial system.

MATERIALS AND

METHODS

Computed tomography scans of 123 prostate and 310 head and neck patients were evaluated. Besides one head and neck model, generic DLC models were used. Contouring time using centres' existing clinical methods and contour editing time after DLC were compared. Timing was evaluated using paired and non-paired studies. Commercial software or in-house scripts assessed dice similarity coefficient (DSC) and distance to agreement (DTA). One centre assessed head and neck inter-observer variability.

RESULTS

The mean contouring time saved for prostate structures using DLC compared to the existing clinical method was 5.9 ± 3.5 min. The best agreement was shown for the femoral heads (median DSC 0.92 ± 0.03, median DTA 1.5 ± 0.3 mm) and the worst for the rectum (median DSC 0.68 ± 0.04, median DTA 4.6 ± 0.6 mm). The mean contouring time saved for head and neck structures using DLC was 16.2 ± 8.6 min. For one centre there was no DLC time-saving compared to an atlas-based method. DLC contours reduced inter-observer variability compared to manual contours for the brainstem, left parotid gland and left submandibular gland.

CONCLUSIONS

Generic prostate and head and neck DLC models can provide time-savings which can be assessed with paired or non-paired studies to integrate with clinical workload. Reducing inter-observer variability potential has been shown.

Для цитирования: Walker Zoe, Bartley Gary, Hague Christina, Kelly Daniel, Navarro Clara, Rogers Jane, South Christopher, Temple Simon, Whitehurst Philip, Chuter Robert. Evaluating the Effectiveness of Deep Learning Contouring across Multiple Radiotherapy Centres.. Physics and imaging in radiation oncology. 2022. DOI: 10.1016/j.phro.2022.11.003.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.