MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1378/chest.10-0371

Медицинская библиотека · Chest · 2010

Release of metal particles from needles used for transbronchial needle aspiration.

Gounant Valérie, Ninane Vincent, Janson Xavier, Colombat Magali, Wislez Marie, Grunenwald Dominique, Bernaudin Jean François, Cadranel Jacques, Fleury-Feith Jocelyne

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Although mediastinoscopy is still the gold standard for diagnosis of mediastinal lymphadenopathy, minimally invasive procedures have been developed: transbronchial needle aspiration (TBNA) using a flexible bronchoscope (conventional TBNA) or linear echoendoscope (endobronchial ultrasound [EBUS]) allowing real-time guided lymph node aspiration. The observation of contamination of samples by foreign particles led us to determine the frequency and the nature of this material and to identify its origin.

METHODS

From June 2007 to November 2008, 141 consecutive patients underwent conventional TBNA (n = 84) or EBUS-guided TBNA (EBUS-TBNA) (n = 57). All cytologic samples were reviewed in blinded fashion, and contamination was assessed semiquantitatively. Mineral analysis using a transmission electron microscope equipped with an energy dispersive x-ray spectrometer was performed on the solution obtained after rinsing unused needles and on four samples of calf thymuses punctured with EBUS needles.

RESULTS

Foreign material, different from anthracosis, was identified in samples obtained with five different batches of needles, only from EBUS-TBNA (P < .0001). The contamination score was correlated to the number of passes (P = .035). Mineral analyses of the rinsing solutions from conventional TBNA needles were negative, whereas metal alloys of iron, titanium, nickel, and chromium were released with EBUS needles. The same contamination was identified in three of the four punctured calf thymuses.

CONCLUSIONS

Dedicated EBUS-TBNA needles are able to release metal particles, probably by friction between the stylet and the needle, with a potential risk to inject particles into nodes. The long-term consequences are unknown, but the need for safety measures should be evaluated.

Для цитирования: Gounant Valérie, Ninane Vincent, Janson Xavier, Colombat Magali, Wislez Marie, Grunenwald Dominique, Bernaudin Jean François, Cadranel Jacques, Fleury-Feith Jocelyne. Release of metal particles from needles used for transbronchial needle aspiration.. Chest. 2010. DOI: 10.1378/chest.10-0371.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.