MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.surg.2022.08.024

Медицинская библиотека · Surgery · 2022

C11 choline PET/CT succeeds when conventional imaging for primary hyperparathyroidism fails.

Saha Sujata, Vierkant Robert A, Johnson Geoffrey B, Parvinian Ahmad, Wermers Robert A, Foster Trenton, McKenzie Travis, Dy Benzon, Lyden Melanie

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Focused parathyroidectomy in primary hyperparathyroidism is possible with accurate preoperative localization. A growing body of data exists regarding the role of radio-labeled C11 choline positron emission tomography/computed tomography. In cases of nonlocalized disease, it may be a useful adjunct to ultrasound, (123)I/(99)Tc-sestamibi (I-123 sestamibi), or 4-dimensional computed tomography imaging.

METHODS

Patients who received a neck and chest limited coverage C11 choline positron emission tomography/computed tomography for evaluation of primary hyperparathyroidism from 2017 to 2021 at a single institution were retrospectively reviewed. We assessed the sensitivity, positive predictive value, and false negative rate. We also compared these rates to the standard modalities of ultrasound, I-123 sestamibi, 4-dimensional computed tomography, and examined concordance rates.

RESULTS

We identified 43 patients, of whom 33 had a positive C11 choline positron emission tomography/computed tomography finding. This cohort of patients had failed to localize on multiple standard imaging modalities. Twenty-five patients proceeded to surgery, 72% of whom were reoperative cases. Twenty (80%) achieved an intraoperative cure. Analysis showed that C11 choline positron emission tomography/computed tomography achieved a sensitivity of 64% (95% confidence interval 47%-82%) and positive predictive value of 72% (95% confidence interval 54%-90%). There were 5/25 (20%) false positive positron emission tomography C11 choline results found to be lymph nodes, normal parathyroid, and 1 recurrent laryngeal nerve neuroma.

CONCLUSION

C11 choline positron emission tomography/computed tomography is a useful adjunct for parathyroid localization in a complex population of patients who have failed standard localization techniques including ultrasound, I-123 sestamibi, or 4-dimensional computed tomography and/or prior operations. Although routine inclusion of C11 choline positron emission tomography/computed tomography imaging may not be necessary, it may aid in preoperative localization in the reoperative setting.

Для цитирования: Saha Sujata, Vierkant Robert A, Johnson Geoffrey B, Parvinian Ahmad, Wermers Robert A, Foster Trenton, McKenzie Travis, Dy Benzon, Lyden Melanie. C11 choline PET/CT succeeds when conventional imaging for primary hyperparathyroidism fails.. Surgery. 2022. DOI: 10.1016/j.surg.2022.08.024.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.