MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ejro.2026.100781

Медицинская библиотека · European journal of radiology open · 2026

Characteristics of liver virtual non-contrast images from three-phase dynamic CT obtained with second-generation dual-layer spectral CT.

Tachibana Yuji, Kamei Noritaka, Shiroo Tomoaki, Asayama Yoshiki

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To clarify the characteristics of virtual non-contrast (VNC) images generated from each phase of triphasic dynamic liver computed tomography (CT) using second-generation dual-layer spectral CT (DLCT).

METHODS

A second-generation DLCT system, the Spectral CT 7500, was used for the three-phase dynamic liver CT examination of 31 patients from August 2024 to February 2025. VNC images were generated from the arterial phase (AP), portal venous phase (PVP), and equilibrium phase (EP). For a quantitative evaluation, the agreement between liver parenchymal CT values from the VNC images created from the three phases and the true non-contrast (TNC) images was assessed by a Bland-Altman analysis (pre-set clinical limit: ±10 HU). In the qualitative evaluation, five parameters (vascular remnants, visibility of the portal and hepatic veins, image noise, image distortion, and overall image quality) were assessed using a four-point rating scale.

RESULTS

In the quantitative analysis, the mean difference (bias) between the VNC and TNC images was -2.19 for AP, -0.14 for PVP, and -2.11 HU for EP, and the 95% limits of agreement were within the pre-set clinical limit for all phases. In the qualitative analysis, vascular remnants were significantly more pronounced in the AP and PVP compared to the EP. Consequently, vessel visibility and overall image quality were significantly higher in the VNC images derived from the EP.

CONCLUSION

Although incomplete removal of vascular contrast enhancement was noted (arterial in the AP and venous in the PVP/EP), VNC images from DLCT are quantitatively interchangeable with TNC images.

Для цитирования: Tachibana Yuji, Kamei Noritaka, Shiroo Tomoaki, Asayama Yoshiki. Characteristics of liver virtual non-contrast images from three-phase dynamic CT obtained with second-generation dual-layer spectral CT.. European journal of radiology open. 2026. DOI: 10.1016/j.ejro.2026.100781.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.