Use of a retrievable vena cava filter with low-intensity anticoagulation for prevention of pulmonary embolism in patients with cancer: an observational study in 106 cases.

Damascelli Bruno, Ticha Vladimira, Patelli Gianluigi, Lanocita Rodolfo, Morosi Carlo, Civelli Enrico, Di Tolla Giuseppe, Frigerio Laura Francesca, Ciceri Elisa, Garbagnati Francesco, Spreafico Carlo, Amadeo Paola, Marchianò Alfonso

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate a retrievable inferior vena cava (IVC) filter in combination with low-intensity oral anticoagulation for prevention of pulmonary embolism (PE) in patients with malignancy complicated by thromboembolic disease.

MATERIALS AND

METHODS

From October 2005 to December 2009, 107 Bard G2 filters were placed in 106 patients. Forty-eight patients had deep vein thrombosis (DVT) alone, 53 had PE with DVT, and five had PE with no evidence of DVT. After an initial period of anticoagulation with heparin, low-intensity oral anticoagulant therapy to achieve a target International Normalized Ratio of 1.5-2.0 was instituted. Follow-up computed tomography to evaluate the pulmonary circulation, IVC, and lower limbs was performed at 3 and 6 months.

RESULTS

PE recurred in three of 58 patients (5.2%). None of the 48 patients with DVT alone developed PE, nor was there any recurrence of DVT. The filter was removed in 14 patients (13.2%). No complications occurred during the retrieval procedure. A total of 16 complications occurred in seven patients: one migration (0.9%); four cases of vena cava thrombosis (3.7%), three of which were associated with recurrent PE (2.8%); one filter fracture (0.9%); and one IVC penetration (0.9%). Filter tilting greater than 15° occurred in six patients (5.7%) and was associated with other complications in five (4.7%).

CONCLUSIONS

In patients with malignancies complicated by venous thromboembolic disease, an IVC filter together with low-intensity anticoagulation may be a possible treatment strategy for PE prophylaxis. Controlled studies are warranted.

Для цитирования: Damascelli Bruno, Ticha Vladimira, Patelli Gianluigi, Lanocita Rodolfo, Morosi Carlo, Civelli Enrico, Di Tolla Giuseppe, Frigerio Laura Francesca, Ciceri Elisa, Garbagnati Francesco, Spreafico Carlo, Amadeo Paola, Marchianò Alfonso. Use of a retrievable vena cava filter with low-intensity anticoagulation for prevention of pulmonary embolism in patients with cancer: an observational study in 106 cases.. Journal of vascular and interventional radiology : JVIR. 2011. DOI: 10.1016/j.jvir.2011.04.015.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.