MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jvir.2011.01.459

Медицинская библиотека · Journal of vascular and interventional radiology : JVIR · 2011

Photothermal ablation with the excimer laser sheath technique for embedded inferior vena cava filter removal: initial results from a prospective study.

Kuo William T, Odegaard Justin I, Louie John D, Sze Daniel Y, Unver Kamil, Kothary Nishita, Rosenberg Jarrett K, Hovsepian David M, Hwang Gloria L, Hofmann Lawrence V

СтатьяVideo-Audio MediaПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the safety and effectiveness of the excimer laser sheath technique for removing embedded inferior vena cava (IVC) filters.

MATERIALS AND

METHODS

Over 12 months, 25 consecutive patients undergoing attempted IVC filter retrieval with a laser-assisted sheath technique were prospectively enrolled into an institutional review board-approved study registry. There were 10 men and 15 women (mean age 50 years, range 20-76 years); 18 (72%) of 25 patients were referred from an outside hospital. Indications for retrieval included symptomatic filter-related acute caval thrombosis (with or without acute pulmonary embolism), chronic IVC occlusion, and bowel penetration. Retrieval was also performed to remove risks from prolonged implantation and potentially to eliminate need for lifelong anticoagulation. After failure of standard methods, controlled photothermal ablation of filter-adherent tissue with a Spectranetics laser sheath and CVX-300 laser system was performed. All patients were evaluated with cavography, and specimens were sent for histologic analysis.

RESULTS

Laser-assisted retrieval was successful in 24 (96%) of 25 patients as follows: 11 Günther Tulip (mean 375 days, range 127-882 days), 4 Celect (mean 387 days, range 332-440 days), 2 Option (mean 215 days, range 100-330 days), 4 OPTEASE (mean 387 days, range 71-749 days; 1 failed 188 days), 2 TRAPEASE (mean 871 days, range 187-1,555 days), and 2 Greenfield (mean 12.8 years, range 7.2-18.3 years). There was one (4%) major complication (acute thrombus, treated with thrombolysis), three (12%) minor complications (small extravasation, self-limited), and one adverse event (coagulopathic retroperitoneal hemorrhage) at follow-up (mean 126 days, range 13-302 days). Photothermal ablation of filter-adherent tissue was histologically confirmed in 23 (92%) of 25 patients.

CONCLUSIONS

The laser-assisted sheath technique appears to be a safe and effective tool for retrieving embedded IVC filters, including permanent types, with implantation ranging from months to > 18 years.

Для цитирования: Kuo William T, Odegaard Justin I, Louie John D, Sze Daniel Y, Unver Kamil, Kothary Nishita, Rosenberg Jarrett K, Hovsepian David M, Hwang Gloria L, Hofmann Lawrence V. Photothermal ablation with the excimer laser sheath technique for embedded inferior vena cava filter removal: initial results from a prospective study.. Journal of vascular and interventional radiology : JVIR. 2011. DOI: 10.1016/j.jvir.2011.01.459.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.