MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jvir.2009.05.037

Медицинская библиотека · Journal of vascular and interventional radiology : JVIR · 2009

Comparison of the recovery and G2 filter as retrievable inferior vena cava filters.

Cantwell Colin P, Pennypacker Jason, Singh Harjit, Scorza Leslie B, Waybill Peter N, Lynch Frank C

Сравнительное исследованиеКонтролируемое клиническое исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To compare the technical success of the Recovery and G2 filters as retrievable inferior vena cava (IVC) filters.

MATERIALS AND

METHODS

Recovery (n = 128) and G2 (n = 113) filters were placed in the IVCs of 241 patients with the intent of retrieval. The referring physician and/or patient were contacted at 6-month intervals to ensure filter retrieval when indicated. The Recovery and G2 filter groups were compared regarding technical success of filter placement, technical success of attempted retrieval, filter tilt, filter migration, filter fracture, and filter efficacy.

RESULTS

Filter placement was technically successful in 95% of Recovery filters (n = 122) and 100% of G2 filters (n = 113). Recovery filter retrieval was attempted in 55% of patients (n = 71) at a mean of 228 days (range, 0-838 d) after filter placement. G2 filter retrieval was attempted in 55% of patients (n = 62) at a mean of 230 days (range, 7-617 d) after filter placement. Technical success rates of filter retrieval were 94% (n = 67) and 97% (n = 60) in the Recovery and G2 filter groups, respectively. The G2 filter group had significantly fewer cases of (i) filter tilt at placement, (ii) filter tilt at attempted retrieval, and (iii) filter fracture than the Recovery filter group. In the G2 filter group, there was a significantly higher technical success rate of filter placement and there were more cases of caudal filter migration than in the Recovery filter group.

CONCLUSIONS

Compared with the Recovery filter, the G2 filter is associated with significantly less filter fracture and tilt, greater technical success of filter placement, and more caudal filter migration.

Для цитирования: Cantwell Colin P, Pennypacker Jason, Singh Harjit, Scorza Leslie B, Waybill Peter N, Lynch Frank C. Comparison of the recovery and G2 filter as retrievable inferior vena cava filters.. Journal of vascular and interventional radiology : JVIR. 2009. DOI: 10.1016/j.jvir.2009.05.037.