Comparison of radiation dose for implant imaging using conventional spiral tomography, computed tomography, and cone-beam computed tomography.

Chau Anson C M, Fung Karl

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

The objective of this study was to compare typical patient radiation dose delivered in implant imaging with spiral computed tomography (CT), conventional spiral tomography, and cone-beam CT (CBCT).

STUDY

DESIGN

The Scanora (Orion Corporation Soredex, Helsinki, Finland), Spiral HiSpeed/Fxi (General Electric, Milwaukee, WI), and Classic iCAT (Imaging Sciences International, Hatfield, PA) units were selected to represent conventional spiral tomography, spiral CT, and CBCT, respectively. Thermoluminescent dosimeters were used in a Rando phantom to measure radiation-absorbed doses to the lenses, parotid glands, submandibular glands, sublingual gland, and the thyroid for maxillary and mandibular implant imaging techniques.

RESULTS

Spiral CT delivered the highest absorbed dose, whereas CBCT delivered the lowest in both maxillary and mandibular implant scans. The salivary glands received the highest absorbed doses. Scanora delivered lower radiation doses than CBCT when the anterior region of the maxilla or mandible was irradiated.

CONCLUSION

In implant imaging, CT delivers the highest radiation dose to the salivary glands, whereas the CBCT system studied delivers the lowest dose. Irrespective of imaging modality, during implant imaging as conducted for this study, salivary glands receive most radiation.

Для цитирования: Chau Anson C M, Fung Karl. Comparison of radiation dose for implant imaging using conventional spiral tomography, computed tomography, and cone-beam computed tomography.. Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics. 2009. DOI: 10.1016/j.tripleo.2008.11.009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.