DOI 10.1378/chest.13-2306

Медицинская библиотека · Chest · 2014

B-mode ultrasound assessment of diaphragm structure and function in patients with COPD.

Baria Michael R, Shahgholi Leili, Sorenson Eric J, Harper Caitlin J, Lim Kaiser G, Strommen Jeffrey A, Mottram Carl D, Boon Andrea J

Оценочное исследованиеСтатьяНаблюдательное исследованиеПоддержка NIH: внешняя программаПеревод пока не подготовлен

Аннотация

BACKGROUND

Electromyographic evaluation of diaphragmatic neuromuscular disease in patients with COPD is technically difficult and potentially high risk. Defining standard values for diaphragm thickness and thickening ratio using B-mode ultrasound may provide a simpler, safer means of evaluating these patients.

METHODS

Fifty patients with a diagnosis of COPD and FEV₁ < 70% underwent B-mode ultrasound. Three images were captured both at end expiration (Tmin) and at maximal inspiration (Tmax). The thickening ratio was calculated as (Tmax/Tmin), and each set of values was averaged. Findings were compared with a database of 150 healthy control subjects.

RESULTS

There was no significant difference in diaphragm thickness or thickening ratio between sides within groups (control subjects or patients with COPD) or between groups, with the exception of the subgroup with severe air trapping (residual volume > 200%), in which the only difference was that the thickening ratio was higher on the left (P = .0045).

CONCLUSIONS

In patients with COPD presenting for evaluation of coexisting neuromuscular respiratory weakness, the same values established for healthy control subjects serve as the baseline for comparison. This knowledge expands the role of ultrasound in evaluating neuromuscular disease in patients with COPD.

Для цитирования: Baria Michael R, Shahgholi Leili, Sorenson Eric J, Harper Caitlin J, Lim Kaiser G, Strommen Jeffrey A, Mottram Carl D, Boon Andrea J. B-mode ultrasound assessment of diaphragm structure and function in patients with COPD.. Chest. 2014. DOI: 10.1378/chest.13-2306.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.