Modification of 24-h ambulatory blood pressure and heart rate during contraception with the vaginal ring: a prospective study.

Cagnacci Angelo, Zanin Renata, Napolitano Antonella, Arangino Serenella, Volpe Annibale

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Hypertension is recognized as a major risk factor for coronary, cerebral and renal vascular disease. Hormonal methods of contraception may increase the risk for cardiovascular events. We evaluated whether the combined hormonal contraceptive vaginal ring that releases 15-mcg ethinylestradiol and 120 mcg of etonogestrel each day influences 24-h ambulatory blood pressure.

STUDY

DESIGN

At baseline, ambulatory blood pressure was automatically monitored every 30 min for 41 h in 18 normotensive healthy women during their follicular phase (Days 3-6). Each subject was immediately treated with the vaginal ring for six cycles. Monitoring of ambulatory blood pressure was repeated in the last days of the sixth cycle of treatment.

RESULTS

During the vaginal ring, a significant increase was observed for 24-h diastolic (2.75±5.13 mmHg; p=.03) and mean (2.69±5.35 mmHg; p=.048) blood pressure and for daytime diastolic (3.04±6.36 mmHg; p=.05) blood pressure. No variation was found in nighttime blood pressure. Heart rate increased in the 24-h period (3.39±5.85 beats/min; p=.025) and in the daytime (3.38±6.25 beats/min; p=.034) measurements.

CONCLUSIONS

In normotensive women, the vaginal ring slightly increases 24-h blood pressure and heart rate. The underlying mechanisms and the clinical impact of these slight modifications require further evaluation.

Для цитирования: Cagnacci Angelo, Zanin Renata, Napolitano Antonella, Arangino Serenella, Volpe Annibale. Modification of 24-h ambulatory blood pressure and heart rate during contraception with the vaginal ring: a prospective study.. Contraception. 2013. DOI: 10.1016/j.contraception.2013.04.003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.