MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3341/kjo.2025.0072

Медицинская библиотека · Korean journal of ophthalmology : KJO · 2025

Unraveling Active Surge Mitigation Actuation: Optimizing Phacoemulsification with Active Sentry Handpiece.

Elabjer Biljana Kuzmanović, Štrbac Tea, Ćubela Iva, Rak Benedict, Martinčević Dora, Bušić Mladen, Bjeloš Mirjana

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: The purpose of this study is to determine which demographic and biometric factors, lens hardness, complications such as pseudoexfoliation syndrome (PEX) and intraoperative floppy iris syndrome (IFIS), and intraoperative metrics have the greatest influence on active surge mitigation (ASM) actuation during phacoemulsification using the Centurion Vision System with the Active Sentry handpiece.

METHODS

The preoperative analysis considered age, sex, biometric data (obtained using IOLMaster 700 and the Pentacam), and lens hardness according to the Lens Opacification Classification System (LOCS) III. IFIS and PEX were also assessed. Intra-operative metrics during phacoemulsification included total case time, cumulative dissipated energy, total ultrasound time, and the number of ASM actuations.

RESULTS

Significant positive correlations were found between ASM and both LOCS III grade (p = 0.001) and age (p = 0.017), albeit a significant negative correlation was observed with anterior chamber depth (p = 0.005). No significant differences in the number of ASM actuations were observed between genders or in patients with PEX or IFIS. In multivariate analysis, an ASM of ≥1 significantly predicted higher LOCS III grade (odds ratio, 1.79; 95% confidence interval, 1.04-2.95), whereas greater anterior chamber depth reduced this likelihood (odds ratio, 0.311; 95% confidence interval, 0.100-0.960).

CONCLUSIONS

ASM actuation is more frequent with advanced lens hardness and old age, while a deep anterior chamber reduces actuations compared to a shallow one. Lens hardness affects ASM more than anterior chamber depth, and no significant correlation was found between PEX, IFIS, and ASM.

Для цитирования: Elabjer Biljana Kuzmanović, Štrbac Tea, Ćubela Iva, Rak Benedict, Martinčević Dora, Bušić Mladen, Bjeloš Mirjana. Unraveling Active Surge Mitigation Actuation: Optimizing Phacoemulsification with Active Sentry Handpiece.. Korean journal of ophthalmology : KJO. 2025. DOI: 10.3341/kjo.2025.0072.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.