Early Vitrectomy in Endophthalmitis: Visual Outcomes and Complication Rates.

Sromicki Julian W, Stahel Marc, Blum Robert A, Rudolph Katrin A, Barthelmes Daniel

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

This study examined visual outcomes and complication rates after early pars plana vitrectomy (PPV) in eyes with endophthalmitis.

METHODS

The study was designed as a single-center, retrospective, observational database study. A total of 92 eyes treated with early PPV for endophthalmitis at the University Hospital Zurich between 2006 and 2016 were included. Endophthalmitis cases following cataract surgery (CAT, n = 44), intravitreal injection (IVI, n = 12), trabeculectomy (TRAB, n = 6), and Others (e.g., trauma or endogenous, n = 30) were assessed. Visual acuity (VA) and intraocular pressure (IOP) from prior to endophthalmitis to 12 months after PPV were analyzed. Secondary outcomes included complications following the procedure.

RESULTS

CAT and IVI groups showed good visual outcomes. Final VA in CAT and IVI groups was not statistically different to prior to endophthalmitis (CAT p = 0.840, IVI p = 0.933). In the CAT group, 78.9% of eyes with a starting VA of > light perception achieved ≥ 20/40 final VA. The highest rate of patients with at least one complication was observed in TRAB (100%), followed by Others (63.3%), IVI (50.0%), and CAT groups (40.9%).

CONCLUSION

Early PPV may be beneficial in endophthalmitis following cataract surgery and intravitreal injection, regardless of initial VA.

Для цитирования: Sromicki Julian W, Stahel Marc, Blum Robert A, Rudolph Katrin A, Barthelmes Daniel. Early Vitrectomy in Endophthalmitis: Visual Outcomes and Complication Rates.. Ophthalmology and therapy. 2025. DOI: 10.1007/s40123-025-01196-x.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.