Comparison of visual performance among three higher-order aspheric enhanced monofocal intraocular lenses and a standard aspheric monofocal lens.
Аннотация
PURPOSE: To compare visual performance among 3 types of higher-order aspheric enhanced monofocal intraocular lenses (IOLs) and a standard aspheric monofocal IOL.
SETTING
Hayashi Eye Hospital, Fukuoka, Japan.
DESIGN
Randomized comparative study.
METHODS
344 eyes of 172 patients scheduled for phacoemulsification were randomly assigned to one of the 4 groups according to the IOL type: 3 types of enhanced monofocal IOL, (1) Eyhance, (2) Impress, and (3) NSP-3, and a standard monofocal IOL, (4) Tecnis monofocal. At 2 months postoperatively, monocular and binocular distance-corrected visual acuity (VA) from far to near simulated distances, photopic and mesopic contrast VA, and degree of halo and glare symptoms were measured and compared among groups.
RESULTS
Mean monocular and binocular distance-corrected intermediate VA at 0.5, 0.7, and 1.0 m was essentially better in the 3 enhanced monofocal IOL groups than in the standard monofocal IOL group ( P ≤ .04), whereas mean far and near distance-corrected VAs at 0.3, 2.0, 3.0, 5.0, and ∞ m did not differ significantly among the 4 groups. Mean photopic and mesopic contrast VA and the size and intensity of halo and glare symptoms did not differ significantly among groups.
CONCLUSIONS
The 3 enhanced monofocal IOL types evaluated provided significantly better intermediate VA than a standard monofocal IOL with no significant deterioration in contrast sensitivity or photic symptoms. All visual performance test results examined were comparable among the 3 enhanced monofocal IOL types, suggesting that enhanced monofocal IOLs can serve as a replacement for standard monofocal IOLs.