MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/cid.13118

Медицинская библиотека · Clinical implant dentistry and related research · 2022

Clinical, radiographic, and biochemical evaluation of two-piece versus one-piece single implants with a laser-microgrooved collar surface after 5 years of functional loading.

Guarnieri Renzo, Reda Rodolfo, Di Nardo Dario, Miccoli Gabriele, Zanza Alessio, Testarelli Luca

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

AIM: To compare the clinical and radiographic conditions and the expression of pro-inflammatory cytokines in peri-implant crevicular fluid (PICF) at two-piece/bone level (TP/BL) versus one-piece/tissue level (OP/TL) single implants with a laser-microgrooved collar after at least 5 years of loading.

MATERIALS AND

METHODS

In total, 20 single TP/BL implants and 20 contralateral OP/TL implants, both with a laser-microgrooved collar surface, in 20 systemically and periodontally healthy subjects (12 males and 8 females, between the age of 36 and 64 [mean age of 49.7 ± 12.3 years]), were examined. Levels of IL-1β, IL-1RA, IL-6, IL-8, IL-17, b-FGF, G-CSF, GM-CSF, IFN, MIP-1β, TNF-α, and VEGF were assessed in PICF using the Bio-Plex 200 Suspension Array System. Plaque index (PI), probing depth (PD), bleeding on probing (BOP), and gingival recession (REC) were recorded. Radiographic crestal bone levels (CBL) were assessed at the mesial and distal aspects of the implant sites.

RESULTS

The mean PI, PD, BOP, and REC values had no significant differences in either group. A higher mean value of CBL with statistical difference was detected for TP/BL compared with OP/TL implants. The levels of IL-1β, IL-6, IL-8, GM-CSF, and MIP-1β and TNF-α were higher at TP/BL implants than at OP/TL implants. However, only IL-1β, IL-6, and TNF-α values presented significant differences between the groups.

CONCLUSIONS

Although after 5 years of loading single TP/BL and OP/TL implants with a laser-microgrooved collar surface presented similar good clinical conditions, a higher proinflammatory state and higher crestal bone loss were detected for TP/BL implants.

Для цитирования: Guarnieri Renzo, Reda Rodolfo, Di Nardo Dario, Miccoli Gabriele, Zanza Alessio, Testarelli Luca. Clinical, radiographic, and biochemical evaluation of two-piece versus one-piece single implants with a laser-microgrooved collar surface after 5 years of functional loading.. Clinical implant dentistry and related research. 2022. DOI: 10.1111/cid.13118.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.