MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/aor.14343

Медицинская библиотека · Artificial organs · 2022

Does the distance between residency and implanting center affect the outcome of patients supported by left ventricular assist devices? A multicenter Italian study on radial mechanically assisted circulatory support (MIRAMACS) analysis.

Lechiancole Andrea, Loforte Antonio, Scandroglio Mara, Comisso Marina, Iacovoni Attilio, Maiani Massimo, Gliozzi Gregorio, De Bonis Michele, Musumeci Francesco, Terzi Amedeo, Pacini Davide, Livi Ugolino

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Patients with LVAD require continuous monitoring and care, and since Implanting Centers (ICs) are more experienced in managing LVAD patients than other healthcare facilities, the distance between patient residency and IC could negatively affect the outcomes.

METHODS

Data of patients discharged after receiving an LVAD implantation between 2010 and 2021 collected from the MIRAMACS database were retrospectively analyzed. The population was divided into two groups: A (n = 175) and B (n = 141), according to the distance between patient residency and IC ≤ or >90 miles. The primary endpoint was freedom from Adverse Events (AEs), a composite outcome composed of death, cerebrovascular accident, hospital admission because of GI bleeding, infection, pump thrombosis, and right ventricular failure. Secondary endpoints were incidences of mortality and complications. All patients were followed-up regularly, according to participating center protocols.

RESULTS

Baseline clinical characteristics and indications for LVAD did not differ between the two groups. The mean duration of support was 25.5 ± 21 months for Group A and 25.7 ± 20 months for Group B (p = 0.79). At 3 years, freedom from AEs was similar between Group A and Group B (p = 0.36), and there were no differences in rates of mortality and LVAD-related complications.

CONCLUSIONS

Distance from the IC does not represent a barrier to successful outcomes as long as regular and continuous follow-up is provided.

Для цитирования: Lechiancole Andrea, Loforte Antonio, Scandroglio Mara, Comisso Marina, Iacovoni Attilio, Maiani Massimo, Gliozzi Gregorio, De Bonis Michele, Musumeci Francesco, Terzi Amedeo, Pacini Davide, Livi Ugolino. Does the distance between residency and implanting center affect the outcome of patients supported by left ventricular assist devices? A multicenter Italian study on radial mechanically assisted circulatory support (MIRAMACS) analysis.. Artificial organs. 2022. DOI: 10.1111/aor.14343.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.