MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s12149-020-01479-2

Медицинская библиотека · Annals of nuclear medicine · 2020

Preoperative F-18 fluorocholine PET/CT for the detection of hyperfunctioning parathyroid glands in patients with secondary or tertiary hyperparathyroidism: comparison with Tc-99m sestamibi scan and neck ultrasound.

Chen Yu-Hung, Chen Hwa-Tsung, Lee Ming-Che, Liu Shu-Hsin, Wang Ling-Yi, Lue Kun-Han, Chan Sheng-Chieh

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

Currently, neck ultrasound is the preferred preoperative imaging in patients with secondary/tertiary hyperparathyroidism, and the use of Tc-99m sestamibi scan is limited in these patients. We conducted this study to compare the diagnostic utilities of F-18 fluorocholine PET/CT, Tc-99m sestamibi scintigraphy, and neck ultrasound for localizing hyperfunctioning parathyroid glands in secondary/tertiary hyperparathyroidism.

METHODS

We prospectively enrolled 30 dialysis patients with a diagnosis of secondary/tertiary hyperparathyroidism; of these, 27 participants underwent all three imaging modalities, including dual-phase F-18 fluorocholine PET/CT (PET acquired 5 and 60 min after tracer injection), dual-phase Tc-99 m sestamibi SPECT/CT, and neck ultrasound. All patients underwent parathyroidectomy after imaging. We compared the lesion-based sensitivity, specificity, and accuracy of the three image tools using histopathology as the reference.

RESULTS

A total of 27 patients (107 lesions) underwent all three imaging modalities and entered the final analysis. The lesion-based sensitivities of F-18 fluorocholine PET/CT, Tc-99m sestamibi, and ultrasound were 86%, 55%, and 62%, respectively (both p < 0.001, when comparing F-18 fluorocholine PET/CT to Tc-99 m sestamibi scan and to ultrasound). F-18 fluorocholine PET/CT, Tc-99m sestamibi, and ultrasound had similar specificities of 93%, 80%, and 87%, respectively. The accuracy of F-18 fluorocholine PET/CT (87%) was significantly higher than that of Tc-99m sestamibi (59%) and ultrasound (65%) (both p < 0.001). F-18 fluorocholine PET/CT identified more hyperplastic glands than ultrasound in 52% (14/27) patients. The sensitivity of F-18 fluorocholine PET/CT reached 95% for hyperplastic parathyroid masses as low as 200 mg.

CONCLUSIONS

F-18 fluorocholine PET/CT shows superior accuracy over the conventional imaging modalities in patients with secondary or tertiary hyperparathyroidism. The combination of F-18 fluorocholine PET/CT and neck ultrasound may enable better surgical planning in these patients.

REGISTRATION IDENTIFICATION NUMBER: NCT04316845.

Для цитирования: Chen Yu-Hung, Chen Hwa-Tsung, Lee Ming-Che, Liu Shu-Hsin, Wang Ling-Yi, Lue Kun-Han, Chan Sheng-Chieh. Preoperative F-18 fluorocholine PET/CT for the detection of hyperfunctioning parathyroid glands in patients with secondary or tertiary hyperparathyroidism: comparison with Tc-99m sestamibi scan and neck ultrasound.. Annals of nuclear medicine. 2020. DOI: 10.1007/s12149-020-01479-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.