MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00402-022-04665-1

Медицинская библиотека · Archives of orthopaedic and trauma surgery · 2022

Distal locking technique affects the rate of iatrogenic radial nerve palsy in intramedullary nailing of humeral shaft fractures.

Greiner Fabian, Kaiser Georg, Kleiner Anne, Brugger Jonas, Aldrian Silke, Windhager Reinhard, Hajdu Stefan, Schreiner Markus

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Intramedullary humeral nailing is a common and reliable procedure for the treatment of humeral shaft fractures. Radial nerve palsy is a common complication encountered in the treatment of this pathology. The radial nerve runs from posterior to anterior at the lateral aspect of the distal humerus. Hence, there is reason to believe that due to the anatomic vicinity of the radial nerve in this area, lateral-medial distal locking in intramedullary nailing of the humerus may be associated with a greater risk for iatrogenic radial nerve injury compared to anterior-posterior locking.

QUESTIONS/PURPOSE: To assess whether the choice of distal locking (lateral-medial versus anterior-posterior distal locking) in intramedullary humeral nailing of humeral shaft fractures affects the risk for iatrogenic radial nerve injury.

PATIENTS AND

METHODS

Overall, 203 patients (116 females, mean age 64.3 ± 18.6 years), who underwent intramedullary nailing of the humerus between 2000 and 2020 at a single level-one trauma center, met the inclusion criteria and were analyzed in this retrospective case-control study. Patients were subdivided into two groups according to the distal locking technique.

RESULTS

Anterior-posterior locking was performed in 176 patients versus lateral-medial locking in 27 patients. We observed four patients with iatrogenic radial nerve palsy in both groups. Risk for iatrogenic radial nerve palsy was almost 7.5 times higher for lateral-medial locking (OR 7.48, p = 0.006). There was no statistically significant difference regarding intraoperative complications, union rates or revision surgeries between both groups.

CONCLUSIONS

Lateral-medial distal locking in intramedullary nailing of the humerus may be associated with a greater risk for iatrogenic radial nerve palsy than anterior-posterior locking. Hence, we advocate for anterior-posterior locking.

LEVEL OF EVIDENCE: Level III retrospective comparative study.

Для цитирования: Greiner Fabian, Kaiser Georg, Kleiner Anne, Brugger Jonas, Aldrian Silke, Windhager Reinhard, Hajdu Stefan, Schreiner Markus. Distal locking technique affects the rate of iatrogenic radial nerve palsy in intramedullary nailing of humeral shaft fractures.. Archives of orthopaedic and trauma surgery. 2022. DOI: 10.1007/s00402-022-04665-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.