MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · American heart journal · 2002

Health values before and after pacemaker implantation.

Lopez-Jimenez Francisco, Goldman Lee, Orav E John, Ellenbogen Kenneth, Stambler Bruce, Marinchak Roger, Wilkoff Bruce L, Mangione Carol M, Yoon Catherine, Vitale Kimberly, Lamas Gervasio A

Клиническое исследованиеСтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Health value or utility is the abstracted magnitude of a person's preference for quality and quantity of life. It reflects how much lifetime with the patient's current health condition a patient is willing to exchange for a life in excellent health. Health values are used in cost-effectiveness analysis as a means of calculating quality-adjusted years of life.

OBJECTIVE

This study assessed the health values of elderly patients before and after pacemaker implantation.

METHODS

We prospectively examined 398 patients from the Pacemaker Selection in the Elderly study, in which patients were randomized to either VVIR or DDDR mode. Health values were estimated with the time tradeoff method before implantation and at 3, 9, and 18 months after implantation.

RESULTS

The mean age of patients was 76 +/- 6 years; 234 patients (59%) were male. At baseline, patients were, on average, willing to exchange 5 years of current health for approximately 4 years in perfect health (value 0.76 +/- 0.06). There was no difference in baseline health values with implant diagnosis (sinus node dysfunction n = 172, 0.72, atrioventricular block n = 227, 0.75, other diagnoses n = 39, 0.78, P = not significant). The overall improvement in health values at 3 months after pacemaker implantation was 0.165 +/- 0.4 (P =.0001). The improvement in health values was independent of pacing mode (P =.6). The time tradeoff score was modestly correlated with other measurements of health-related quality of life. The change in time tradeoff score with time was not influenced by demographic characteristics such as age and sex, diagnoses, pacing mode, employment status, or history of angina. Patients with a lower functional class at enrollment (III or IV on the Specific Activity Scale) demonstrated an absolute improvement of 23% in their health values, whereas patients in class I or II improved only by 12%, (P =.03).

CONCLUSIONS

Permanent pacemaker implantation for standard indications improves health values and descriptive health status measures. The values reported here may be used as a means of calculating the cost-effectiveness of different pacing modalities.

Для цитирования: Lopez-Jimenez Francisco, Goldman Lee, Orav E John, Ellenbogen Kenneth, Stambler Bruce, Marinchak Roger, Wilkoff Bruce L, Mangione Carol M, Yoon Catherine, Vitale Kimberly, Lamas Gervasio A. Health values before and after pacemaker implantation.. American heart journal. 2002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.