MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/00006231-200011000-00009

Медицинская библиотека · Nuclear medicine communications · 2000

A simplified method for processing dynamic images of gastric antrum.

Madsen J L, Graff J, Fugisang S

Клиническое исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

By means of a dynamic acquisition protocol and a Fourier transform algorithm the scintigraphic technique can be used to assess gastric antral motility. In previous approaches, however, the definition of a region of interest (ROI) that gives rise to an unequivocal result of the analysis of the corresponding time-activity curve might be crucial. To overcome this problem we evaluated a new technique based on a fixed box-ROI and a simple weighting principle. Eight healthy volunteers ingested a meal that contained a 99Tcm-stannous colloid labelled omelette. Gastric emptying was assessed from static images taken at 30-mm intervals for 2 h. Anterior dynamic frames of 1 s each, which were acquired for 5 mm after each static acquisition, were used to determine the frequency of antral contractions. In order to allow for precise outlining of the antrum, each set of dynamic images was at first reframed into a single 5-mm image. The same ROI (20 pixels vertical, 15 pixels horizontal) was then positioned over the distal portion of the antrum on each reframed image. On each 1-s frame the obtained counts in each of the 15 columns of 20 pixels were summed. Then the localization of the geometric centre of radioactivity in the 15 columns was determined. On the assumption that the horizontal oscillations of the geometric centre of radioactivity in the ROI reflected the contractile activity of the antrum, the frequency of these contractions was calculated by fast Fourier transform analysis of the obtained time versus geometric centre curve. In all subjects, our technique gave unequivocal frequencies of antral contractions at each time point. Statistical analysis did not reveal any intraindividual variation in this frequency during gastric emptying. We believe that the simplified scintigraphic method is an advantageous alternative for assessing the frequency of antral contractions.

Для цитирования: Madsen J L, Graff J, Fugisang S. A simplified method for processing dynamic images of gastric antrum.. Nuclear medicine communications. 2000. DOI: 10.1097/00006231-200011000-00009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.