[Atrial sensing and atrioventricular synchrony in single lead VDD pacemakers. Can the appearance of atrial undersensing be predicted?].

Wiegand U K, Schneider R, Bode F, Brandes A, Taubert G, Potratz J

Сравнительное исследованиеАннотация на английскомСтатьяПеревод пока не подготовлен

Аннотация

Single-lead VDD-pacing is an alternative to DDD-systems in patients with AV-block and normal sinus node function. Atrial sensing plays a central role in these pacemakers. AV-synchrony, incidence of atrial arrhythmias and the occurrence of sinus node disease were investigated in 108 patients with VDD-pacemakers followed over a mean period of 24.8 months after implantation. Determinants influencing the occurrence of atrial undersensing were especially focused on. Mean atrial potential and sensing threshold were reduced within the first 2 weeks after implantation (p < 0.01). Intermittent atrial undersensing occurred in 25.9% of patients and was observed in 82.1% of these patients within the first 2 weeks after implantation. Positioning the atrial dipole in the low right atrium showed a significantly higher incidence of atrial undersensing (42% in comparison to 24% in the other positions). In a multivariate analysis including intra- and postoperative measurements as well as characteristics of the pacemakers and leads, it was the only parameter significantly (p < 0.02) correlated to the occurrence of atrial undersensing. Atrial fibrillation was observed in 4.6% of patients, a sinus node disease became evident in 2.7% of patients; 92.6% of patients remained in the AV-synchronous mode. Intermittent atrial undersensing is common in single-lead VDD-pacemakers and difficult to provide during implantation. The atrial dipole should not be positioned in the low right atrium and highest atrial sensitivity should generally be programmed. Nevertheless, VDD-pacing achieves an AV-synchrony comparable to DDD-pacemakers.

Для цитирования: Wiegand U K, Schneider R, Bode F, Brandes A, Taubert G, Potratz J. [Atrial sensing and atrioventricular synchrony in single lead VDD pacemakers. Can the appearance of atrial undersensing be predicted?].. Zeitschrift fur Kardiologie. 1997. DOI: 10.1007/s003920050039.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.