Electrophysiological effects of propofol on the normal cardiac conduction system.

Pires L A, Huang S K, Wagshal A B, Kulkarni R S

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

To determine the electrophysiological effects of propofol and to explain the potential mechanism(s) whereby it causes bradyarrhythmias, 10 closed-chest pigs weighing 20-25 kg were studied. Each animal was premedicated by intramuscular administration of ketamine hydrochloride, intubated, and mechanically ventilated. Femoral arterial and venous catheters were placed, and a comprehensive electrophysiologic evaluation was performed at baseline and after two doses (1 mg/kg i.v. bolus and 0.1 mg/kg/min infusion and an extra 1- mg/kg i.v. bolus and 0.2 mg/kg/min infusion) of propofol. The electrophysiological effects obtained on low-and high-dose propofol were compared to baseline values. Propofol caused a dose-related decrease in sinus cycle length (baseline 565 +/- 36 ms, low-dose propofol 541 +/- 28, high-dose propofol 527 +/- 26 ms; p < 0.05), a prolongation of the corrected sinus node recovery time (baseline 119 +/- 35 ms, low-dose propofol 126 +/- 32, high-dose propofol 130 +/- 30 ms; p < 0.01), and an increase in the His-ventricular interval (baseline 33 +/- 4 ms, low-dose propofol 36 +/- 4, high-dose propofol 40 +/- 3 ms; p < 0.005). All other electrophysiological parameters remained unchanged, and there were no cases of spontaneous atrioventricular block or sinus pauses. We conclude that propofol causes dose-related depression of sinus node and His-Purkinje system functions, but has no effect on the atrioventricular node function and on the conduction properties of atrial and ventricular tissues in normal pig hearts.

Для цитирования: Pires L A, Huang S K, Wagshal A B, Kulkarni R S. Electrophysiological effects of propofol on the normal cardiac conduction system.. Cardiology. 1996. DOI: 10.1159/000177113.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.