MedElevator Войти в исследования
← Поиск публикаций

DOI 10.20524/aog.2020.0538

Медицинская библиотека · Annals of gastroenterology · 2020

Luminal-apposing stents for benign intraluminal strictures: a large United States multicenter study of clinical outcomes.

Mizrahi Meir, Fahmawi Yazan, Merritt Lindsey, Kumar Manoj, Tharian Benjamin, Khan Salman Ali, Inamdar Sumant, Sharma Neil, Uppal Dushant, Shami Vanessa M, Kashif Mahmood Syed, Gabr Moamen, Pleskow Douglas, Berzin Tyler M, James Ted W, Croglio Michael, Baron Todd H, Adler Douglas G

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The use of fully covered lumen-apposing metal stents (LAMS) for benign short gastrointestinal (GI) strictures has been reported. This study aimed to evaluate the safety and efficacy of LAMS for refractory GI strictures.

METHODS

A retrospective analysis was performed of patients who underwent LAMS placement for benign GI strictures in 8 United States centers. The primary outcomes were technical success and initial clinical response. Secondary outcomes were reintervention rate and adverse events.

RESULTS

A total of 51 patients underwent 61 LAMS placement procedures; 33 (64.7%) had failed previous treatments. The most common stricture location was the pylorus (n=17 patients). Various sizes of stents were used, with 15-mm LAMS placed in 45 procedures, 20-mm LAMS in 14 procedures, and 10-mm LAMS in 2 procedures. The overall technical success, short-term clinical response and reintervention rate after stent removal were 100%, 91.8% and 31.1%, respectively. Adverse events were reported in 17 (27.9%) procedures, with stent migration being the most common (13.1%). In subgroup analysis, both 15 mm and 20 mm stents had comparable short-term clinical response and adverse event rates. However, stent migration (15.6%) was the most common adverse event with 15-mm LAMS while pain (14.3%) was the most common with 20-mm LAMS. The reintervention rate was 80% at 200-day follow up after stent removal.

CONCLUSIONS

Using LAMS for treatment of short benign GI strictures is safe and effective. Larger LAMS, such as the new 20 mm in diameter, may have a lower stent migration rate compared to smaller diameter LAMS.

Для цитирования: Mizrahi Meir, Fahmawi Yazan, Merritt Lindsey, Kumar Manoj, Tharian Benjamin, Khan Salman Ali, Inamdar Sumant, Sharma Neil, Uppal Dushant, Shami Vanessa M, Kashif Mahmood Syed, Gabr Moamen, Pleskow Douglas, Berzin Tyler M, James Ted W, Croglio Michael, Baron Todd H, Adler Douglas G. Luminal-apposing stents for benign intraluminal strictures: a large United States multicenter study of clinical outcomes.. Annals of gastroenterology. 2020. DOI: 10.20524/aog.2020.0538.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.