MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jmri.10214

Медицинская библиотека · Journal of magnetic resonance imaging : JMRI · 2002

Motion of the distal renal artery during three-dimensional contrast-enhanced breath-hold MRA.

Vasbinder G Boudewijn C, Maki Jeffrey H, Nijenhuis Robbert J, Leiner Tim, Wilson Gregory J, Kessels Alfons G H, Lemaire Etienne E L E, Kaandorp Dave W, Ho Kai Yiu J A M, van Engelshoven Jos M A

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To study the potential detrimental effects of renal motion on breath-hold three-dimensional contrast-enhanced (CE) magnetic resonance angiography (MRA).

MATERIALS AND

METHODS

A computer model simulating linear motion was applied to MRA pulse sequences. Subsequently, to study whether renal motion was present, 24 patients being evaluated for possible renovascular hypertension underwent a breath-hold nonenhanced single slice two-dimensional dynamic turbo field-echo magnetic resonance imaging (MRI) scan with a typical duration of 32 seconds. This sequence was followed by breath-hold three-dimensional CE renal MRA. CE-MRA images were evaluated by two independent observers.

RESULTS

The computer model revealed linear renal motion to cause artifacts. The severity of these artifacts correlated with velocity. Significant (P < 0.001) near linear cranial motion of the kidneys and diaphragm during a sustained breath-hold was found for the right kidney, left kidney, right diaphragm, and left diaphragm (0.26 +/- 0.21 mm/second, 0.25 +/- 0.23 mm/second, 0.43 +/- 0.43 mm/second, and 0.29 +/- 0.33 mm/second [mean +/- SD], respectively). CE-MRA images showed artifacts of the distal renal artery that corroborated the computer model findings.

CONCLUSION

The observed cranial motion of the kidneys during a breath-hold adversely affects distal renal artery image quality on three-dimensional CE-MRA and jeopardizes reliable clinical evaluation. Shortening scan time may be beneficial for decreasing image degradation caused by this phenomenon.

Для цитирования: Vasbinder G Boudewijn C, Maki Jeffrey H, Nijenhuis Robbert J, Leiner Tim, Wilson Gregory J, Kessels Alfons G H, Lemaire Etienne E L E, Kaandorp Dave W, Ho Kai Yiu J A M, van Engelshoven Jos M A. Motion of the distal renal artery during three-dimensional contrast-enhanced breath-hold MRA.. Journal of magnetic resonance imaging : JMRI. 2002. DOI: 10.1002/jmri.10214.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.