BACKGROUND

3D visualization systems in laparoscopic surgery have been proposed to improve manual task handling compared to 2D, however, few studies have compared the intra-operative efficacy in laparoscopic cholecystectomy (LC). The aim of this study is to determine if there is a benefit in intra-operative efficiency when using a 3D visualization system in difficult LC compared to traditional 2D visualization systems.

METHODS

Retrospective analysis of 'difficult' LCs (Grades 3 or 4) was completed. The assessor was blinded as all cases were recorded and viewed in 2D only. Variables collected included time to complete steps, missed hook diathermy attempts, failed grasp attempts, missed clip attempts and preparation steps for intra-operative cholangiogram (IOC). Multiple linear regression was undertaken for time variables, Poisson regression or negative binomial regression was completed for continuous variables.

RESULTS

Fifty-two operative videos of 'difficult' LC were reviewed. 3D systems were associated with reduced operative times, although this was not statistically significant (CI: -2.93-14.93, P-value = 0.183). Dissection of the anterior fold to achieve the critical view of safety was significantly faster by 3.55 min (CI: 1.215-9.206, P-value = 0.002), and with considerably fewer errors when using 3D systems. Fewer IOC preparation errors were observed with a 3D system compared with a 2D system.

CONCLUSIONS

3D systems appear to enhance operator efficiency, allowing faster completion of critical steps with fewer errors. This pilot study underscores the utility of video annotation for intra-operative assessment and suggests that, in larger multi-centre studies, 3D systems may demonstrate superior intra-operative efficiency over 2D systems during a 'difficult' LC.

Для цитирования: Patel Meet, Tranter-Entwistle Isaac, Sirimanna Pramudith, Hugh Thomas J. 3D visualization systems improve operator efficiency during difficult laparoscopic cholecystectomy: a retrospective blinded review of surgical videos.. ANZ journal of surgery. 2024. DOI: 10.1111/ans.18949.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.