MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/jcm12144835

Медицинская библиотека · Journal of clinical medicine · 2023

Predictors of Conduction Disturbances Requiring New Permanent Pacemaker Implantation following Transcatheter Aortic Valve Implantation Using the Evolut Series.

Abdelshafy Mahmoud, Elkoumy Ahmed, Elzomor Hesham, Abdelghani Mohammad, Campbell Ruth, Kennedy Ciara, Kenny Gibson William, Fezzi Simone, Nolan Philip, Wagener Max, Arsang-Jang Shahram, Mohamed Sameh K, Mostafa Mansour, Shawky Islam, MacNeill Briain, McInerney Angela, Mylotte Darren, Soliman Osama

СтатьяПеревод пока не подготовлен

Аннотация

(1)

Background

Conduction disturbance requiring a new permanent pacemaker (PPM) after transcatheter aortic valve implantation (TAVI) has traditionally been a common complication. New implantation techniques with self-expanding platforms have reportedly reduced the incidence of PPM. We sought to investigate the predictors of PPM at 30 days after TAVI using Evolut R/PRO/PRO+; (2)

Methods

Consecutive patients who underwent TAVI with the Evolut platform between October 2019 and August 2022 at University Hospital Galway, Ireland, were included. Patients who had a prior PPM (n = 10), valve-in-valve procedures (n = 8) or received >1 valve during the index procedure (n = 3) were excluded. Baseline clinical, electrocardiographic (ECG), echocardiographic and multislice computed tomography (MSCT) parameters were analyzed. Pre-TAVI MSCT analysis included membranous septum (MS) length, a semi-quantitative calcification analysis of the aortic valve leaflets, left ventricular outflow tract, and mitral annulus. Furthermore, the implantation depth (ID) was measured from the final aortography. Multivariate binary logistic analysis and receiver operating characteristic (ROC) curve analysis were used to identify independent predictors and the optimal MS and ID cutoff values to predict new PPM requirements, respectively; (3)

Results

A total of 129 TAVI patients were included (age = 81.3 ± 5.3 years; 36% female; median EuroSCORE II 3.2 [2.0, 5.4]). Fifteen patients (11.6%) required PPM after 30 days. The patients requiring new PPM at 30 days were more likely to have a lower European System for Cardiac Operative Risk Evaluation II, increased prevalence of right bundle branch block (RBBB) at baseline ECG, have a higher mitral annular calcification severity and have a shorter MS on preprocedural MSCT analysis, and have a ID, as shown on the final aortogram. From the multivariate analysis, pre-TAVI RBBB, MS length, and ID were shown to be predictors of new PPM. An MS length of <2.85 mm (AUC = 0.85, 95%CI: (0.77, 0.93)) and ID of >3.99 mm (area under the curve (AUC) = 0.79, (95% confidence interval (CI): (0.68, 0.90)) were found to be the optimal cut-offs for predicting new PPM requirements; (4)

Conclusions

Membranous septum length and implantation depth were found to be independent predictors of new PPM post-TAVI with the Evolut platform. Patient-specific implantation depth could be used to mitigate the requirement for new PPM.

Для цитирования: Abdelshafy Mahmoud, Elkoumy Ahmed, Elzomor Hesham, Abdelghani Mohammad, Campbell Ruth, Kennedy Ciara, Kenny Gibson William, Fezzi Simone, Nolan Philip, Wagener Max, Arsang-Jang Shahram, Mohamed Sameh K, Mostafa Mansour, Shawky Islam, MacNeill Briain, McInerney Angela, Mylotte Darren, Soliman Osama. Predictors of Conduction Disturbances Requiring New Permanent Pacemaker Implantation following Transcatheter Aortic Valve Implantation Using the Evolut Series.. Journal of clinical medicine. 2023. DOI: 10.3390/jcm12144835.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.