MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/pace.14700

Медицинская библиотека · Pacing and clinical electrophysiology : PACE · 2023

Left bundle branch pacing versus biventricular pacing for cardiac resynchronization therapy: A systematic review and meta-analysis.

Parlavecchio Antonio, Vetta Giampaolo, Caminiti Rodolfo, Coluccia Giovanni, Magnocavallo Michele, Ajello Manuela, Pistelli Lorenzo, Dattilo Giuseppe, Foti Rosario, Carerj Scipione, Della Rocca Domenico Giovanni, Crea Pasquale, Palmisano Pietro

МетаанализСистематический обзорСтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

Cardiac resynchronization therapy (CRT) reduces heart failure (HF) hospitalization and all-cause mortality in HF patients with left bundle branch block (LBBB). Biventricular pacing (BVP) is the gold standard for achieving CRT, but about 30%-40% of patients do not respond to BVP-CRT. Recent studies showed that left bundle branch pacing (LBBP) provided remarkable results in CRT. Therefore, we conducted a meta-analysis aiming to compare LBBP-CRT versus BVP-CRT in HF patients.

METHODS

We systematically searched the electronic databases for studies published from inception to December 29, 2022 and focusing on LBBP-CRT versus BVP-CRT in HF patients. The primary endpoint was HF hospitalization. The effect size was estimated using a random-effect model as Risk Ratio (RR) and mean difference (MD).

RESULTS

Ten studies enrolling 1063 patients met the inclusion criteria. Compared to BVP-CRT, LBBP-CRT led to significant reduction in HF hospitalization [7.9% vs.14.5%; RR: 0.60 (95%CI: 0.39-0.93); p = .02], QRSd [MD: 30.26 ms (95%CI: 26.68-33.84); p < .00001] and pacing threshold [MD: -0.60 (95%CI: -0.71 to -0.48); p < .00001] at follow up. Furthermore, LBBP-CRT improved LVEF [MD: 5.78% (95%CI: 4.78-6.77); p < .00001], the rate of responder [88.5% vs.72.5%; RR: 1.19 (95%CI: 1.07-1.32); p = .002] and super-responder [60.8% vs. 36.5%; RR: 1.56 (95%CI: 1.27-1.91); p < .0001] patients and the NYHA class [MD: -0.42 (95%CI: -0.71 to -0.14); p < .00001] compared to BVP-CRT.

CONCLUSION

In HF patients, LBBP-CRT was superior to BVP-CRT in reducing HF hospitalization. Further significant benefits occurred within the LBBP-CRT group in terms of QRSd, LVEF, pacing thresholds, NYHA class and the rate of responder and super-responder patients.

Для цитирования: Parlavecchio Antonio, Vetta Giampaolo, Caminiti Rodolfo, Coluccia Giovanni, Magnocavallo Michele, Ajello Manuela, Pistelli Lorenzo, Dattilo Giuseppe, Foti Rosario, Carerj Scipione, Della Rocca Domenico Giovanni, Crea Pasquale, Palmisano Pietro. Left bundle branch pacing versus biventricular pacing for cardiac resynchronization therapy: A systematic review and meta-analysis.. Pacing and clinical electrophysiology : PACE. 2023. DOI: 10.1111/pace.14700.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.